Ê×Ò³ - ÐÂÎÅ - ÕÐƸ - ÏÂÔØ - ²úÆ· - ³§ÉÌ - ·½°¸ - ÎÄÕª - Çó¹º - Õ¹ÀÀ
Ãâ·Ñ×¢²á µÇ¼ | ¹ã¸æ·þÎñ | ¿Í·þÖÐÐÄ
Öлª¹¤¿ØÍø ¡ú ¹¤¿Ø²úÆ· ¡ú 4·RS232/485תÒÔÌ«Íø´®¿Ú·þÎñÆ÷
²úÆ·Ãû³Æ£º 4·RS232/485תÒÔÌ«Íø´®¿Ú·þÎñÆ÷
ÐÍ ºÅ£º C2000 N340
¼Û ¸ñ£º 0.00
Æ· ÅÆ£º
 
Êղش˲úÆ·     ²é¿´ÊÕ²Ø

C2000 N340ÊÇÒ»ÖÖÎȶ¨¿É¿¿µÄ¸ßÐÔÄܹ¤Òµ¼¶ËÄ´®¿ÚÉ豸ÁªÍø·þÎñÆ÷£¬ËüÌṩRS232/485/422µ½TCP/IPÍøÂçºÍTCP/IPÍøÂçµ½RS232/485/422µÄÊý¾Ý͸Ã÷´«Ê䣬Ëü¿ÉÒÔʹ¾ßÓÐRS232/485/422´®¿ÚµÄÉ豸Á¢¼´¾ß±¸ÁªÈëTCP/IPÍøÂçµÄ¹¦ÄÜ¡£

C2000 N340ÏòÉÏÌṩ10/100MÒÔÌ«Íø½Ó¿Ú£¬ÏòÏÂÌṩ4¸ö±ê×¼RS232//485/422´®Ðпڣ¬Í¨Ñ¶²ÎÊý¿Éͨ¹ý¶àÖÖ·½Ê½ÉèÖá£C2000 N340¿É¹ã·ºÓ¦ÓÃÓÚPLC¿ØÖÆÓë¹ÜÀí¡¢ÃŽûÒ½ÁÆ¡¢Â¥Óî¿ØÖÆ¡¢¹¤Òµ×Ô¶¯»¯¡¢²âÁ¿ÒÇ±í¼°»·¾³¶¯Á¦¼à¿Øϵͳ¡¢ÐÅÏ¢¼Òµç¡¢LEDÐÅÏ¢ÏÔʾÉ豸ºÍCNC¹ÜÀíµÈ¡£

Ìص㣺

→²ÉÓÃARM9´¦ÀíÆ÷+RTOS£¬¾ßÓиüÇ¿´óµÄʵʱ´¦ÀíÄÜÁ¦£»

→¾ßÓÐTCP Server¡¢TCP Client¡¢UDP¡¢ÐéÄâ´®¿Ú¡¢µã¶ÔµãÁ¬½ÓµÈ5ÖÖ²Ù×÷ģʽ £»

→Óû§»ùÓÚÍøÂçµÄÈí¼þ¡£²»ÐèÒª×öÈκÎÐ޸ľͿÉÒÔÓëC2000 N340ͨѶ£»

→ͨ¹ý°²×°ÎÒÃÇÃâ·ÑÌṩµÄÐéÄâ´®¿ÚÈí¼þ£¬Óû§»ùÓÚ´®¿ÚµÄÈí¼þ²»ÐèÒª×öÈκÎÐ޸ľͿÉÒÔÓëC2000 N340ͨѶ£»

→¶ÔÓÚÐèÒª¿ª·¢Èí¼þµÄÓû§£¬ÎÒÃÇÃâ·ÑÌṩͨѶ¶¯Ì¬¿â¡¢ÉèÖö¯Ì¬¿â»òOCX¿Ø¼þ£»

→ͨ¹ýä¯ÀÀÆ÷¡¢ÉèÖÃÈí¼þ»òÉèÖö¯Ì¬¿â½øÐвÎÊýÐÞ¸ÄÉèÖã»

→Ö§³ÖDNSÓòÃû½âÎö¹¦ÄÜ£»

→µÍ¹¦ºÄÉè¼Æ£¬ÎÞÐèÉ¢ÈÈ×°Öã»

→¿´ÃŹ·Éè¼Æ£¬Îȶ¨ÐԸߣ»

→µçÔ´¾ßÓÐÁ¼ºÃµÄ¹ýÁ÷¹ýѹ¡¢·À·´½Ó±£»¤¹¦ÄÜ¡£

a)  ±¾²úÆ·ÓÐÒÔÏÂÈýÖÖ¹¤×÷ģʽ£º 

1£®×÷ΪTCP·þÎñÆ÷£¬×ª»»Æ÷ÉϵçºóÔÚÖ¸¶¨µÄTCP ¶Ë¿ÚµÈ´ýÊý¾Ý·þÎñÆ÷µÄÁ¬½ÓÇëÇó£¬Êý¾Ý·þÎñÆ÷ÔÚÐèÒªÓëת»»Æ÷ͨѶµÄʱºò£¬Ïòת»»Æ÷µÄ¼àÌý¶Ë¿ÚÇëÇó½¨Á¢TCP Á¬½Ó£¬Á¬½Ó½¨Á¢ºó£¬Êý¾Ý·þÎñÆ÷¿ÉÒÔËæʱÏòת»»Æ÷·¢ËÍÊý¾Ý£¬×ª»»Æ÷Ò²¿ÉÒÔËæʱ½«Êý¾Ý·¢Ë͵½Êý¾Ý·þÎñÆ÷£¬ÔÚÍê³ÉÖ¸¶¨µÄͨѶºó£¬Êý¾Ý·þÎñÆ÷¿ÉÒÔÖ÷¶¯ÒªÇó¶Ï¿ªÁ¬½Ó£¬·ñÔòÁ¬½ÓÒ»Ö±±£³Ö¡£

2£®×÷ΪTCP¿Í»§¶Ë£¬×ª»»Æ÷Éϵçʱ»áÖ÷¶¯Ïò·þÎñÆ÷ÇëÇóÁ¬½Ó£¬Ö±µ½TCPÁ¬½Ó½¨Á¢ÎªÖ¹£¬²¢ÇÒÁ¬½ÓÒ»µ©½¨Á¢½«Ò»Ö±±£³Ö£¬Á¬½Ó½¨Á¢ºó£¬Êý¾Ý·þÎñÆ÷¿ÉÒÔËæʱÏòת»»Æ÷·¢ËÍÊý¾Ý£¬×ª»»Æ÷Ò²¿ÉÒÔËæʱ½«Êý¾Ý·¢Ë͵½Êý¾Ý·þÎñÆ÷£» 

3£®UDP·½Ê½ÓÐÁ½ÖÖ£º

µ±C2000 ¹¤×÷ÔÚ“UDP normal”ģʽʱ£¬C2000»á»ØÓ¦ËùÓеÄIPµØÖ·ºÍ¶Ë¿Ú·¢¹ýÀ´µÄÊý¾Ý£¬²¢½«·µ»ØµÄÊý¾Ý·¢Ë͵½×îºóÒ»´Î·¢¸øËü²éѯÇëÇóµÄIPµØÖ·ºÍ¶Ë¿Ú¡£

µ±C2000 ¹¤×÷ÔÚ“UDP Appointed”ģʽʱ£¬ËüÄܽÓÊÕËùÓеÄIPµØÖ·ºÍ¶Ë¿Ú·¢¹ýÀ´µÄÊý¾Ý£¬µ«Ö»½«·µ»ØµÄÊý¾Ý·¢Ë͸øÖ¸¶¨µÄIPµØÖ·ºÍ¶Ë¿Ú¡£

b)  Ó¦ÓÃÈí¼þ¿ÉʹÓÃÈýÖÖ·½Ê½Óëת»»Æ÷ͨѶ£º 

1£®Í¨¹ý±¾¹«Ë¾¿ª·¢µÄÐéÄâ´®¿Ú¹ÜÀí³ÌÐò£¬½«ÍøÂçÊý¾ÝÖض¨Ïòµ½ÐéÄâ´®¿Ú£¬È»ºó´ÓÐéÄâ´®¿Ú¶ÁÈ¡Êý¾Ý¡£

2£®Óñ¾¹«Ë¾¿ª·¢µÄ¿Ø¼þEDSockServer.ocx(»ò¶¯Ì¬¿âEDSockServer.dll)¡£

3£®Ê¹ÓÃSocket½øÐÐͨѶ¡£

 

 

 

 

1.2 ¼¼Êõ²ÎÊý

ϵͳ

CPU

32-bit ARM

RAM

32MB

Flash

32MB

LAN

ÒÔÌ«Íø

10/100Mbps×ÔÊÊÓ¦£¬RJ45

±£»¤

ÄÚÖÃ1.5KVµç´Å¸ôÀë±£»¤

´®¿Ú½Ó¿Ú

´®¿ÚÊýÁ¿

4¸ö

´®¿ÚЭÒé

4¸öRS232/485/422

´®¿ÚͨѶ²ÎÊý

 

УÑé

None£¬Even£¬Odd£¬Mark£¬Space

Êý¾Ýλ

6£¬7£¬8

ֹͣλ

1¡¢2

Á÷Á¿¿ØÖÆ

RTS/CTS£¬XON/XOFF£¬None

ËÙÂÊ

300bpsÖÁ115200bps

Èí¼þÌصã

ЭÒé

ARP£¬IP£¬ICMP£¬TCP£¬UDP£¬DHCP£¬HTTP£¬DNS

²Ù×÷ģʽ

TCP Server£¬TCP Client£¬UDP£¬ÐéÄâ´®¿Ú£¬µã¶ÔµãÁ¬½Ó

É趨

C2000ÉèÖóÌÐò£¬Webä¯ÀÀÆ÷£¬ÉèÖö¯Ì¬¿â¡¢´®¿ÚÉèÖ㨿ÉÑ¡£©

ÌṩÈí¼þ

ÐéÄâ´®¿ÚÈí¼þ¡¢C2000ÉèÖóÌÐò¡¢´®¿Úµ÷ÊÔ¹¤¾ß¡¢ÍøÂç²âÊÔ³ÌÐò¡¢EDSockServer.OCXºÍEDSockServer.DLL¡¢ÉèÖö¯Ì¬¿âÒÔ¼°VB¡¢VC¡¢BC¡¢DelphiµÄʾÀý´úÂë

Çý¶¯Ö§³Ö

Windows 98/ME/2000/XP/2003/Vista/Windows 7 32λ

µçÔ´ÐèÇó

µçÔ´¹æ¸ñ

220VAC,50~60HZ

×î´ó¹¦ÂÊ

< 5W

¹¤×÷»·¾³

²Ù×÷ζȡ¢Êª¶È

-25¡æ~85¡æ£¬5~95%RH²»Äý¶

´æ´¢Î¶ȡ¢Êª¶È

-60¡æ~125¡æ£¬5~95%RH²»Äý¶

Íâ¹Û

³ß´ç

44×20.5×4cm

 

Öʱ£

5Äê

 

´®¿ÚÏßÐòͼ

RJ45Ë®¾§Í·ÏßÐò˵Ã÷£º

¶Ë¿ÚºÅ

ÏßÐò˵Ã÷

 

 

S1£º³È°×

S2£º³È

S3£ºÂÌ°×

S4£ºÀ¶

S5£ºÀ¶°×

S6£ºÂÌ

S7£º×Ø°×

S8£º×Ø

 

 

RJ45→RS232½Ó¿Ú£º£¨RS232Ë®¾§Í·ÏßÐò£©

RJ45Òý½Å

1

2

3

4

5

6

7

8

232 Òý½Å

DSR

RTS

GND

TXD

RXD

¿Õ

CTS

DTR

 

RJ45→RS485/422½Ó¿Ú£º£¨RS485/422Ë®¾§Í·ÏßÐò£©

RJ45Òý½Å

1

2

3

4

5

6

7

8

485/422

δʹÓÃ

485+/T+

GND

485-/T-

R+

R-

δʹÓÃ

δʹÓÃ

RJ45תDB9´®¿ÚÏߣ¬ÓÐÁ½ÖÖ£º

£¨1£©Ë®¾§Í·Ò»²à°Ë¸ùÏ߶¼È«µÄ£¬DB9ͷΪ±ê×¼RS232½Ó¿Ú£¬ÏßÐòÈçÏ£º

1

¿Õ½Å

 

2

½ÓÊÕÊý¾Ý

RXD

3

·¢ËÍÊý¾Ý

TXD

4

¿Õ½Å

 

5

ÐźŵØ

GND

6

¿Õ½Å

 

7

ÇëÇó·¢ËÍ

RTS

8

Çå³ý·¢ËÍ

CTS

9

¿Õ½Å

 

 

£¨2£©Ë®¾§Í·Ò»²àÖ»ÓÐÎå¸ùÏߵģ¬DB9ͷΪ±ê×¼RS485/422½Ó¿Ú£¬ÏßÐòÈçÏ£º

1

485-/T-

2

458+/T+

3

R+

4

R-

5

GND

6

δʹÓÃ

7

δʹÓÃ

8

δʹÓÃ

9

δʹÓÃ

 

 

 

 

 

 

 

 

 

 

 

 

 

¸Å Êö

C2000 N340ÊÇÒ»ÖÖÎȶ¨¿É¿¿µÄ¸ßÐÔÄܹ¤Òµ¼¶ËÄ´®¿ÚÉ豸ÁªÍø·þÎñÆ÷£¬ËüÌṩRS232/485/422µ½TCP/IPÍøÂçºÍTCP/IPÍøÂçµ½RS485/422µÄÊý¾Ý͸Ã÷´«Ê䣬Ëü¿ÉÒÔʹ¾ßÓÐRS485/232/422´®¿ÚµÄÉ豸Á¢¼´¾ß±¸ÁªÈëTCP/IPÍøÂçµÄ¹¦ÄÜ¡£
C2000 N340ÏòÉÏÌṩ10/100MÒÔÌ«Íø½Ó¿Ú£¬ÏòÏÂÌṩ4¸ö±ê×¼RS485/232/422´®Ðпڣ¬Í¨Ñ¶²ÎÊý¿Éͨ¹ý¶àÖÖ·½Ê½ÉèÖᣠC2000 N340 ¿É¹ã·ºÓ¦ÓÃÓÚPLC¿ØÖÆÓë¹ÜÀí¡¢ ÃŽûÒ½ÁÆ¡¢ Â¥Óî×Ô¿Ø¡¢ ¹¤Òµ×Ô¶¯»¯¡¢ ²âÁ¿ÒÇ±í¼°»·¾³¶¯Á¦¼à¿Øϵͳ¡¢ ÐÅÏ¢¼Òµç¡¢ LEDÐÅÏ¢ÏÔʾÉ豸ºÍCNC¹ÜÀíµÈ¡£

 

¡¡ÌØ µã

→²ÉÓÃARM9´¦ÀíÆ÷+RTOS£¬¾ßÓиüÇ¿´óµÄʵʱ´¦ÀíÄÜÁ¦
→¾ßÓÐTCP Server£¬TCP Client¡¢UDP¡¢ÐéÄâ´®¿Ú¡¢µã¶ÔµãÁ¬½ÓµÈÎåÖÖ²Ù×÷ģʽ£»
→Óû§»ùÓÚÍøÂçµÄÈí¼þ£¬²»ÐèÒª×öÈκÎÐ޸ľͿÉÒÔÓëC2000 N340ͨѶ£»
→ͨ¹ý°²×°ÎÒÃÇÃâ·ÑÌṩµÄÐéÄâ´®¿ÚÈí¼þ£¬Óû§»ùÓÚ´®¿ÚµÄÈí¼þ²»ÐèÒª×öÈκÎÐ޸ľͿÉÒÔÓëC2000 N340ͨѶ£»
→¶ÔÓÚÐèÒª¿ª·¢Èí¼þµÄÓû§£¬ÎÒÃÇÃâ·ÑÌṩͨѶ¶¯Ì¬¿â¡¢ÉèÖö¯Ì¬¿â»òOCX¿Ø¼þ£»
→ͨ¹ýä¯ÀÀÆ÷¡¢ÉèÖÃÈí¼þ»òÉèÖö¯Ì¬¿â½øÐвÎÊýÉèÖã»
→µÍ¹¦ºÄÉè¼Æ£¬ÎÞÐèÉ¢ÈÈ×°Öã»
→¾ßÓп´ÃŹ·Éè¼Æ£¬Îȶ¨ÐԸߣ»
→µçÔ´¾ßÓйýÁ÷¹ýѹ±£»¤ºÍ·À·´½Ó¹¦ÄÜ

 

¡¡Ó¦ ÓÃ

 

 

→PLC¿ØÖÆÓë¹ÜÀí
→ÃŽûÒ½ÁÆ
→Â¥Óî×Ô¿Ø
→¹¤Òµ×Ô¶¯»¯
→²âÁ¿ÒÇ±í¼°»·¾³¶¯Á¦¼à¿Øϵͳ
→ÐÅÏ¢¼Òµç
→LEDÐÅÏ¢ÏÔʾÉ豸
→CNC¹ÜÀí

 

 

¡¡¼¼Êõ²ÎÊý

· ÏµÍ³

¡¡CPU

32-bit ARM

 

¡¡RAM 

32MB 

 

¡¡Flash 

2MB 

 


·LAN

¡¡ÒÔÌ«Íø

10/100Mbps×ÔÊÊÓ¦£¬RJ45

 

¡¡±£»¤ 

ÄÚÖÃ1.5KVµç´Å¸ôÀë±£»¤

 


· ´®¿Ú

¡¡´®¿Ú

RS-485/422/232

 

¡¡´®¿ÚÊýÁ¿

4¸ö 

 

   ½çÃæ

4¸öRS232/485/422

 

· ´®¿ÚͨѶ²ÎÊý

¡¡Ð£ Ñé

None£¬Even£¬Odd£¬Mark£¬Space

 

¡¡Êý¾Ýλ

6£¬7£¬8

 

¡¡Í£Ö¹Î»

1£¬2

 

¡¡Á÷Á¿¿ØÖÆ

XON/XOFF£¬RTS/CTS£¬None

 

¡¡ËÙ ÂÊ

300 bps ÖÁ115200 bps

 

· Èí¼þÌصã

¡¡Ð­Òé

ARP£¬IP£¬ICMP£¬TCP£¬UDP£¬DHCP£¬HTTP£¬DNS

 

¡¡²Ù×÷ģʽ

TCP Server£¬TCP Client£¬UDP£¬ÐéÄâ´®¿Ú£¬µã¶ÔµãÁ¬½Ó

 

   ÉèÖÃ

Webä¯ÀÀÆ÷£¬´®¿ÚÉèÖÃ(¿ÉÑ¡)£¬C2000ÉèÖóÌÐò£¬ÉèÖö¯Ì¬¿â

 

¡¡ÌṩÈí¼þ

ÐéÄâ´®¿ÚÈí¼þ¡¢C2000ÉèÖóÌÐò¡¢´®¿Úµ÷ÊÔ¹¤¾ß¡¢ÍøÂç²âÊÔ³ÌÐò¡¢EDSockServer.OCX¿Ø¼þ£¬EDSockServer.DLL¶¯Ì¬¿â¡¢ÉèÖö¯Ì¬¿âÒÔ¼°VB¡¢VC¡¢BC¡¢DelphiµÄʾÀý´úÂë

 

¡¡Çý¶¯Ö§³Ö

Windows98/ME/2000/XP/2003/Win7/Vista

 

· µçÔ´ÐèÇó

¡¡µçÔ´¹æ¸ñ

AC176V~264V(50/60Hz)

 


· »·¾µ

²Ù×÷ζȡ¢Êª¶È

-25¡æ~80¡æ£¬5~95%RH£¬²»Äý¶

 

´¢´æζȡ¢Êª¶È

-60¡æ~125¡æ£¬5~95%RH£¬²»Äý¶

 

  ·ÆäËü

¡¡±£ÐÞ

5Äê±£ÖÊ

 

¡¡³ß´ç

44 X 20.5 X4cm

 

 

 

 


¹«Ë¾¼ò½é
²úƷĿ¼
¹©Ó¦ÐÅÏ¢

¹«Ë¾Ãû³Æ£º ÉîÛÚÊÐÖÐÁª´´Ð¼¼ÊõÓÐÏÞ¹«Ë¾
µç »°£º 1800 2579611 / Àî²ý½ð
ÊÖ»ú£º 18002579611
µØ Ö·£º ¹ã¶«Ê¡ÉîÛÚÊи£ÌïÇø²ÊÌï·ÖÐÒø´óÏÃA×ù16²ã
ÓÊ ±à£º 518000
Ö÷ Ò³£º http://www.ed-168.com/

¸Ã³§ÉÌÏà¹Ø²úÆ·£º
  • 2·RS485תÍøÂç 485תÒÔÌ«Íø ´®¿ÚתRJ45·þÎñÆ÷
  •  
  • RS485/422תÒÔÌ«Íø RJ45ÍøÂç µ¥¿Ú´®¿ÚÁªÍø·þÎñÆ÷
  •  
  • RS232תRJ45 ¹¤Òµ¼¶ 232תÍøÂç ´®¿Ú·þÎñÆ÷
  •  
  • ´®¿ÚÊý¾ÝÍøÂç͸Ã÷´«ÊäоƬ
  •  
  • ´ø¹âµç¸ôÀëRS232תRS485´®¿Úת»»
  •  
  • RS485תRS232 ÓÐÔ´ÐÍ´®¿Úת»»Æ÷
  •  
  • 2·¿ª¹ØÁ¿²É¼¯Ä£¿é Êý×ÖÁ¿×ªÒÔÌ«Íø
  •  
  • ÒÔÌ«Íøת8·¿ª¹ØÁ¿Êä³ö ¿ª¹Ø¿ØÖÆ
  •  
  • µ¥¿Ú485תÒÔÌ«Íø תTCPÍøÂç ¹¤Òµ¼¶
  •  
  • ¹¤Òµ¼¶100M RS232תRJ45 232תÍøÂç ´®¿Ú·þÎñÆ÷
  •  
    ¸ü¶à²úÆ·...
      ¹ØÓÚÎÒÃÇ | ÁªÏµÎÒÃÇ | ¹ã¸æ·þÎñ | ±¾Õ¾¶¯Ì¬ | ÓÑÇéÁ´½Ó | ·¨ÂÉÉùÃ÷ | ·Ç·¨ºÍ²»Á¼ÐÅÏ¢¾Ù±¨  
    ¹¤¿ØÍø¿Í·þÈÈÏߣº0755-86369299
    °æȨËùÓÐ ¹¤¿ØÍø Copyright@ Gkong.com, All Rights Reserved