Ê×Ò³ - ÐÂÎÅ - ÕÐƸ - ÏÂÔØ - ²úÆ· - ³§ÉÌ - ·½°¸ - ÎÄÕª - Çó¹º - Õ¹ÀÀ
Ãâ·Ñ×¢²á µÇ¼ | ¹ã¸æ·þÎñ | ¿Í·þÖÐÐÄ
Öлª¹¤¿ØÍø ¡ú ¹¤¿Ø²úÆ· ¡ú R911172194 R-IL PB BK DI8 D04/CN-PAC×ÜÏßÄ£¿é
²úÆ·Ãû³Æ£º R911172194 R-IL PB BK DI8 D04/CN-PAC×ÜÏßÄ£¿é
ÐÍ ºÅ£º R911172194 R-IL PB BK DI8 D04/CN-PAC
¼Û ¸ñ£º 0.00
Æ· ÅÆ£º
 
Êղش˲úÆ·     ²é¿´ÊÕ²Ø

Á¦Ê¿ÀÖR911172194 R-IL PB BK DI8 D04/CN-PAC×ÜÏßÄ£¿é£»ÉϺ£Î¤Ã×»úµçÉ豸ÓÐÏÞ¹«Ë¾Ö÷ÓªÏúÊÛ²úÆ·£¬²úƷʵÅÄ£¬Ô­×°ÕýÆ·£¬¿Í»§ÂòµÄ°²ÐÄ£¬ÓõķÅÐÄ¡£³£ÓòúÆ·ÏÖ»õ¹©Ó¦£¬»¶Ó­ÐÂÀÏ¿Í»§Ñ¯¼Û²É¹º£¡

²úÆ·¼ò½é:

Á¦Ê¿ÀÖREXROTH×ÜÏßÄ£¿é
R911172194 R-IL PB BK DI8 D04/CN-PAC
Inline PROFIBUS ×ÜÏßñîºÏÆ÷
8 ·ÊäÈ룺24 V DC
4 ·Êä³ö£º24 V DC£¬500 mA
2¡¢3 Ïß½ÓÍ·
Å䱸ÍêÕûµÄ¸½¼þ£¨Á¬½Ó²åÍ·ºÍÌù±êÀ¸£©
Á¬Ðø¶Ë×ÓµãÌù±ê
×ÜÏßñîºÏÆ÷ R-IL PB BK DI8 DO4/CN-PAC ¿ÉÁ¬½Ó PROFIBUS-DP ºÍ Inline °²×°ÏµÍ³¡£Ê¹ÓøÃ×ÜÏßñîºÏ¿É½«ÖÃÓÚÈκÎλÖÃµÄ 62 ̨ Inline ²ÎÓëÉ豸Á¬½ÓÖÁÏÖÓÐ PROFIBUS-DP¡£¸Ã×ÜÏßñîºÏÆ÷ºÍ Inline ²ÎÓëÉ豸×éºÏ³ÉÒ»¸ö°üº¬ 63 ̨±¾µØ×ÜÏß²ÎÓëÉ豸µÄ¹¤×÷Õ¾¡£Òò´Ë£¬×ÜÏßñîºÏÆ÷µÄÊäÈëºÍÊä³ö½«±»ÊÓΪ±¾µØ×ÜÏß²ÎÓëÉ豸¡£
ÖØÁ¿  320g    
´«¸ÐÆ÷Á¬½Ó·½Ê½  2 ÏßÖÆ¡¢3 ÏßÖƼ¼Êõ
Ö´ÐÐÆ÷Á¬½Ó·½Ê½  2 ÏßÖÆ¡¢3 ÏßÖƼ¼Êõ
»·¾³Î¶ȣ¨ÔËÐÐʱ£©  -25 ... +60°C
»·¾³Î¶ȣ¨´¢²Ø/ÔËÊäʱ£©  -45 ... +85°C
ÈÝÐíµÄÏà¶Ôʪ¶È£¨ÔËÐÐʱ£©  95 %£¬²»½á¶
ÈÝÐíµÄÏà¶Ôʪ¶È£¨´¢²Ø/ÔËÊäʱ£©  95 %£¬²»½á¶
Æøѹ£¨ÔËÐУ©  70 kPa ... 106 kPa£¨×î¶à¸ßÓÚ»ùÏß 3000 m£©
¿ÕÆøѹÁ¦£¨´¢²Ø/ÔËÊäʱ£©  70 kPa ... 106 kPa£¨×î¶à¸ßÓÚ»ùÏß 3000 m£©
·À»¤ÀàÐÍ  IP20, IEC 60529
·À»¤µÈ¼¶  III, IEC 61140

Á¦Ê¿ÀÖREXROTHµçÔ´Â˲¨Æ÷
NFD03
ÊÊÓÃÓÚ IndraDrive C, HCS02
ÊÊÓÃÓÚ IndraDrive C, HCS03
R911286918 NFD03.1-480-016
µçÔ´Â˲¨Æ÷È·±£ÁË·ûºÏ EMC ÏÞÖÆ£¬²¢ÇÒÄÜÒÖÖƵçÀµçÈÝÔì³ÉµÄй©µçÁ÷¡£µçÔ´Â˲¨Æ÷¾­×îÓŵ÷ÕûÒÔÊÊÓ¦Çý¶¯¿ØÖƵ¥Ôª£¬²¢ÇÒ¿Éͨ¹ýµçÁ÷¡¢Çý¶¯Æ÷ÊýÁ¿ºÍµç»úµçÀ³¤¶ÈÀ©Õ¹¡£Í¨¹ýÆÁ±Îµç»úµçÀ¿ÉʵÏÖÎÞ¹ÊÕÏÔËÐС£


Á¦Ê¿ÀÖREXROTH¹¦ÄÜÄ£¿éRTÒÔÌ«ÍøºÍPROFIBUS
R911170832 CFL01.1-TP
RTÒÔÌ«Íø£¨PROFINET RT¡¢ÒÔÌ«Íø/IP¡¢ÒÔÌ«Íø TCP/IP£©
PROFIBUS DP
CML¿ØÖÆÆ÷µÄÄ£¿é»¯À©Õ¹
·À»¤µÈ¼¶IP20
ͨ¹ý¸½¼ÓµÄ¼¼ÊõÌØÐÔÀ©Õ¹ÁË¿ØÖƹ¦ÄÜ
À©Õ¹ÁËÓëÆäËû½Ó¿ÚµÄÁ¬½Ó
½«±ê×¼¿ØÖÆÀ©Õ¹µ½SafeLogic°²È«¿ØÖÆÆ÷
¹¦ÄÜÄ£¿é¾ßÓÐʵʱÒÔÌ«ÍøºÍPROFIBUS DPÖ÷É豸»òPROFIBUS DP´ÓÉ豸¹¦ÄÜ¡£¸ù¾ÝÅäÖ㬿ÉÒÔÔÚÄ£¿éÉϽ«²»Í¬µÄÒÔÌ«ÍøЭÒéÓëPROFIBUS DPÒ»ÆðÖ´ÐС£ÒÔÌ«ÍøЭÒé¿ÉÒÔÊÇPROFINET RT¡¢EtherNet/IP»ò±ê×¼TCP/IPµÈ¡£
»·¾³Î¶ȣ¨ÔËÐÐʱ£©  +5 ... +55¡æ
ÈÝÐíµÄÏà¶Ôʪ¶È£¨ÔËÐÐʱ£©  5 % ... 95 %
¹¦ÂÊÏûºÄ  1.65W

Á¦Ê¿ÀÖREXROTH±äƵÆ÷
HCS02 - µ¥Öáת»»Æ÷
1.5 kW ... 11 kW ¹¦ÂÊ·¶Î§
12 A ... 70 A µçÁ÷
200 V ... 500 V Ö±Á÷µçÔ´
2.5x ¹ýÔØÈÝÁ¿
½ô´ÕÐÍÉè¼Æ£¬ÊʺÏÓÚµ¥ÖáÓ¦ÓÃ
IndraDrive C£¨HCS02£©×ª»»Æ÷º­¸ÇÁËÖй¦ÂÊ·¶Î§kW¡£´Ë×°ÖÃÉèÖÃÁËÒ»¸ö¿ØÖƵ¥Ôª²Û£¬Óи÷ÖÖ½Ó¿Ú£¬ÓÃÓÚÁ¬½Ó×Ô¶¯»¯»·¾³£¬ÊÊÓÃÓÚ±àÂëÆ÷ϵͳ¡¢°²È«¼¼Êõ¡¢ºÍÆäËüÊý×Ö¼°Ä£ÄâÐźŵȡ£

Á¦Ê¿ÀÖREXROTHÄ£¿é»¯×ª»»Æ÷
HMS01 µ¥ÖáÄæ±äÆ÷
5.5 kW ... 132 kW ¹¦ÂÊ·¶Î§
12.1 A ... 250 A Á¬ÐøµçÁ÷
12 A ... 350 A ´óµçÁ÷
540 V ... 750 V Ö±Á÷ Ïß·µçѹ
·À»¤µÈ¼¶IP20
HMS01 µ¥ÖáÄæ±äÆ÷ÓÉÖ±Á÷¹©µç£¬²¢Í¨¹ýÖ±Á÷Éú³É±äƵ±ä·ùµÄÊܿؽ»Á÷Êä³öµçѹ£¬ÓÃÓÚÔËÐеç»ú¡£´Ë×°ÖÃÉèÖÃÁËÒ»¸öµ¥Öá¿ØÖƵ¥Ôª²Û£¬Óи÷ÖÖ½Ó¿Ú£¬ÓÃÓÚÁ¬½Ó×Ô¶¯»¯»·¾³£¬ÊÊÓÃÓÚ±àÂëÆ÷ϵͳ¡¢°²È«¼¼Êõ¡¢ºÍÆäËüÊý×Ö¼°Ä£ÄâÐźŵȡ£ÔÚ¶àÖáÓ¦ÓÃÖУ¬Äæ±äÆ÷ͨ¹ý HMV01 »ò HMU05 µçÔ´É豸µÄÖ±Á÷×ÜÏß¹©µç¡£¶ÔÓÚ½ÏСµÄÖá°ü£¬ÒÔ¼°¾ßÓÐÏàÓ¦¶¯Á¦´¢´æµÄ HCS£¬Ò²¿ÉÒÔÓÉ HCS ת»»Æ÷µÄÖ±Á÷×ÜÏß¹©µç¡£

 

Ö÷ÓªÐͺţº

1¡¢Á¦Ê¿ÀÖREXROTHÏÖ³¡×ÜÏßñîºÏÆ÷
R911170875 R-IL S3 BK DI8 DO4-PAC
R911171944 R-IL PN BK DI8 DO4-PAC
R911171726 R-IL ETH BK DI8 DO4 2TX-PAC
R911172194 R-IL PB BK DI8 DO4/CN-PAC
R911170971 R-IL PB BK DP/V1-PAC
R911296696 R-IL SE BK
2¡¢Á¦Ê¿ÀÖREXROTHÄ£ÄâÊäÈëÄ£¿é
R911170784 R-IB IL AI 2/SF-PAC
R911170425 R-IB IL AI 2/SF-230-PAC
R911170426 R-IB IL AI 4/EF-PAC
R911172895 R-IB IL AI 4/U-PAC
R911172894 R-IB IL AI 4/I-PAC
R911308494 R-IB IL AI 8/IS-PAC
R911308493 R-IB IL AI 8/SF-PAC
R911170432 R-IB IL SGI 2/F-PAC
3¡¢Á¦Ê¿ÀÖREXROTHÄ£ÄâÊä³öÄ£¿é
R911172575 R-IB IL AO 1/SF/CN-PAC
R911170436 R-IB IL AO 2/SF-PAC
R911172576 R-IB IL AO 2/SF/CN-PAC
R911170786 R-IB IL AO 2/U/BP-PAC
R911173634 R-IB IL AO 2/UI-PAC
4¡¢Á¦Ê¿ÀÖREXROTHÊý×ÖÊäÈëÄ£¿é
R911170767 R-IB IL 24 DI 2-PAC
R911170750 R-IB IL 24 DI 4-PAC
R911170751 R-IB IL 24 DI 8-PAC
R911171972 R-IB IL 24 DI 8/HD-PAC
R911170752 R-IB IL 24 DI 16-PAC
R911170404 R-IB IL 24 DI 16-NPN-PAC
R911170753 R-IB IL 24 DI 32/HD-PAC
R911170405 R-IB IL 24 DI 32/HD-NPN-PAC
5¡¢Á¦Ê¿ÀÖREXROTHÊý×ÖÊä³öÄ£¿é
R911170754 R-IB IL 24 DO 2-2A-PAC
R911170755 R-IB IL 24 DO 4-PAC
R911170756 R-IB IL 24 DO 8-PAC
R911171973 R-IB IL 24 DO 8/HD-PAC
R911170759 R-IB IL 24 DO 8-2A-PAC
R911170410 R-IB IL 24 DO 8-NPN-PAC
R911170757 R-IB IL 24 DO 16-PAC
R911170768 R-IB IL 24 DO 32/HD-PAC
R911170411 R-IB IL 24 DO 32/HD-NPN-PAC
6¡¢Á¦Ê¿ÀÖREXROTHµçÔ´Ä£¿é/·Ö¶ÎÄ£¿é
¢Å¡¢Á¦Ê¿ÀÖREXROTHµçÔ´Ä£¿é
R911170789 R-IB IL 24 PWR IN-PAC
¢Æ¡¢Á¦Ê¿ÀÖREXROTHÉýѹģ¿é
R911170446 R-IB IL 24 PWR IN/R-PAC
¢Ç¡¢Á¦Ê¿ÀÖREXROTHÉýѹģ¿é
R911172896 R-IB IL 24 PWR IN/R/L-0.8A-PAC
¢È¡¢Á¦Ê¿ÀÖREXROTH·Ö¶ÎÄ£¿é
R911170947 R-IB IL 24 SEG-PAC
¢É¡¢Á¦Ê¿ÀÖREXROTH·Ö¶ÎÄ£¿é£¬ÈÛ¶ÏÆ÷
R911170790 R-IB IL 24 SEG/F-PAC
¢Ê¡¢Á¦Ê¿ÀÖREXROTH·Ö¶ÎÄ£¿é£¬±£ÏÕË¿ – Õï¶Ï
R911170710 R-IB IL 24 SEG/F-D-PAC
¢Ë¡¢Á¦Ê¿ÀÖREXROTHµçλ·ÖÅäÆ÷ (24 V)
R911297189 R-IB IL PD 24V-PAC
¢Ì¡¢Á¦Ê¿ÀÖREXROTHµçλ·ÖÅäÆ÷£¨½ÓµØ£©
7¡¢Á¦Ê¿ÀÖREXROTH¼¼ÊõÄ£¿é
¢Å¡¢Á¦Ê¿ÀÖREXROTH¼ÆÊýÆ÷Ä£¿é
R911170788 R-IB IL CNT-PAC
¢Æ¡¢Á¦Ê¿ÀÖREXROTHÔöÁ¿±àÂëÆ÷¼ì²âÄ£¿é
R911308491 R-IB IL INC-IN-PAC
¢Ç¡¢Á¦Ê¿ÀÖREXROTHÂö¿íµ÷ÖÆ
R911170444 R-IB IL PWM/2-PAC
¢È¡¢Á¦Ê¿ÀÖREXROTHÓÃÓÚ¾ø¶ÔÖµ±àÂëÆ÷µÄ¼ì²âÄ£¿é
R911171514 R-IB IL SSI-IN-PAC
¢É¡¢Á¦Ê¿ÀÖREXROTH¶¨Î»Ä£¿é£¬ÓÃÓÚµ¥ÔÑ/¶àÔѾø¶Ô±àÂëÆ÷
R911308594 R-IB IL SSI-PAC
8¡¢Á¦Ê¿ÀÖREXROTHζÈÄ£¿é
R911170785 R-IB IL TEMP 2 RTD-PAC
R911170431 R-IB IL TEMP 2 UTH-PAC
R911173029 R-IB IL TEMP 4/8 RTD/EF-PAC
R911170428 R-IB IL TEMP 4/8 RTD-PAC
9¡¢Á¦Ê¿ÀÖREXROTHͨÐÅÄ£¿é
R911170445 R-IB IL 24 FLM-PAC
R911171970 R-IB IL 24 FLM MULTI-PAC
R911170948 R-IB IL 24 LSKIP-PAC
R911170440 R-IB IL RS232-PRO-PAC
R911170442 R-IB IL RS485/422-PRO-PAC
R911171971 R-IB IL 24 IOL 4 DI 12-PAC
R911172212 R-IB IL DALI/PWR-PAC
R911172213 R-IB IL DALI-PAC
R911173635 R-IB IL RS UNI-PAC
10¡¢Á¦Ê¿ÀÖREXROTH¼ÌµçÆ÷Ä£¿é
R911170769 R-IB IL 24/230 DOR 1/W-PAC
R911170758 R-IB IL 24/230 DOR4/W-PAC
11¡¢Á¦Ê¿ÀÖREXROTH°²È«Ä£¿é
R911173314 R-IB IL 24 PSDI 16-PAC
R911172846 R-IB IL 24 PSDI 8-PAC
R911172847 R-IB IL 24 PSDO 8-PAC
R911172849 R-IB IL 24 PSDO 4/4-PAC
R911172848 R-IB IL 24 PSDOR 4-PAC
12¡¢Á¦Ê¿ÀÖREXROTH¿éÊäÈë/Êä³öÄ£¿é
R911170874 R-ILB S3 AI4 A02
R911171949 R-ILB S3 AI12 AO4 SSI-IN4
R911170826 R-ILB S3 24 DI16 DIO16
R911171675 R-ILB S3 24 DI16 DIO16/F
R911307402 R-ILB PB 24 DI16 DO16
¢ç¡¢Á¦Ê¿ÀÖREXROTH IndraControl S67 (IP67)ÓÃÓÚÏÖ³¡°²×°µÄÊäÈë/Êä³öϵͳ
1¡¢Á¦Ê¿ÀÖREXROTHÏÖ³¡×ÜÏßñîºÏÆ÷
R911172899 S67-S3-BK-DI8-M8
R911171784 S67-PN-BK-DI8-M8
R911171782 S67-PB-BK-DI8-M8
R911171783 S67-ET-BK-DI8-M8
2¡¢Á¦Ê¿ÀÖREXROTHÄ£ÄâÊäÈëÄ£¿é
R911171793 S67-AI4-U/I-M12
3¡¢Á¦Ê¿ÀÖREXROTHÄ£ÄâÊä³öÄ£¿é
R911171795 S67-AO4-U/I-M12
4¡¢Á¦Ê¿ÀÖREXROTHÊý×ÖÊäÈëÄ£¿é
R911171787 S67-DI8-M8
R911171788 S67-DI8-M12
R911173104 S67-DI8-M12X8
R911173208 S67-DI8-HS-M12
R911172409 S67-DIO8-M8
R911172900 S67-DIO8-M12X8
R911173210 S67-DIO4-HS-M12
5¡¢Á¦Ê¿ÀÖREXROTHÊý×ÖÊä³öÄ£¿é
R911171789 S67-DO8-M8
R911171791 S67-DO8-M8-2A
R911171790 S67-DO8-M12
R911171792 S67-DO8-M12-2A
R911173105 S67-DO8-M12X8
R911173209 S67-DO8-HS-M12
R911172409 S67-DIO8-M8
R911172900 S67-DIO8-M12X8
R911173210 S67-DIO4-HS-M12
6¡¢Á¦Ê¿ÀÖREXROTHµçÔ´Ä£¿é
R911171796 S67-PWR-IN-M12
7¡¢Á¦Ê¿ÀÖREXROTH¼¼ÊõÄ£¿é
¢Å¡¢Á¦Ê¿ÀÖREXROTH HTL ±àÂëÆ÷ / ¼ÆÊýÆ÷Ä£¿é
R911173207 S67-HTL-INC-M12
¢Æ¡¢Á¦Ê¿ÀÖREXROTH TTL ±àÂëÆ÷ / SSI ±àÂëÆ÷Ä£¿é
R911173206 S67-SSI-INC-M12
8¡¢Á¦Ê¿ÀÖREXROTHζÈÄ£¿é
R911171794 S67-AI4-RTD-M12
R911172411 S67-AI4-UTH-M12
9¡¢Á¦Ê¿ÀÖREXROTHͨÐÅÄ£¿é/½Ó¿ÚÄ£¿é
R911173103 S67-RS-UNI-M12
¢è¡¢Á¦Ê¿ÀÖREXROTH Fieldline (IP67)ÓÃÓÚÏÖ³¡°²×°µÄÊäÈë/Êä³öϵͳ
1¡¢Á¦Ê¿ÀÖREXROTH PROFIBUS ÏÖ³¡×ÜÏßñîºÏÆ÷
R911170452 RF-FLM BK PB M12 DI 8 M12
2¡¢Á¦Ê¿ÀÖREXROTH8 Êý×ÖÊäÈëÄ£¿é
R911170449 RF-FLM DI 8 M8
3¡¢Á¦Ê¿ÀÖREXROTH4 ·Êý×ÖÊäÈë¡¢4 ·Êý×ÖÊäÈë/Êä³ö
R911170450 RF-FLM DIO 8/4 M8
¾Å¡¢Á¦Ê¿ÀÖREXROTHËÅ·þÇý¶¯Æ÷
¢å¡¢Á¦Ê¿ÀÖREXROTHÎÞ¹ñʽÇý¶¯¼¼Êõ
1¡¢Á¦Ê¿ÀÖREXROTH¼¯³ÉÁ˵ç»úµÄËÅ·þÇý¶¯Æ÷KSM02
R911378508 KSM02.1B-041C-42N-M1-HG0-ET-L3-D7-AN-FW
R911335755 KSM02.1B-041C-42N-M1-HG0-ET-L3-D7-NN-FW
R911336246 KSM02.1B-041C-42N-M1-HG0-ET-L3-D7-TO-FW
R911335839 KSM02.1B-041C-42N-M1-HG0-ET-NN-D7-NN-FW
R911374653 KSM02.1B-041C-42N-M1-HG0-ET-NN-D7-TO-FW
R911369194 KSM02.1B-041C-42N-M1-HG0-ET-S3-D7-ES-FW
R911339334 KSM02.1B-041C-42N-M1-HG0-ET-S3-D7-NN-FW
R911343874 KSM02.1B-041C-42N-M1-HG0-ET-S3-D7-TO-FW
R911380769 KSM02.1B-041C-42N-M1-HG0-ET-SD-D7-NN-FW
R911379942 KSM02.1B-041C-42N-M1-HG2-ET-L3-D7-AN-FW
R911334434 KSM02.1B-041C-42N-M1-HG2-ET-L3-D7-NN-FW
R911337451 KSM02.1B-041C-42N-M1-HG2-ET-L3-D7-TO-FW
R911335838 KSM02.1B-041C-42N-M1-HG2-ET-NN-D7-NN-FW
R911338749 KSM02.1B-041C-42N-M1-HG2-ET-NN-D7-TO-FW
R911370432 KSM02.1B-041C-42N-M1-HG2-ET-S3-D7-ES-FW
R911339692 KSM02.1B-041C-42N-M1-HG2-ET-S3-D7-NN-FW
R911372422 KSM02.1B-041C-42N-M1-HG2-ET-S3-D7-TO-FW
R911336102 KSM02.1B-041C-42N-M1-HP0-ET-L3-D7-NN-FW
R911336922 KSM02.1B-041C-42N-M1-HP0-ET-L3-D7-TO-FW
R911337452 KSM02.1B-041C-42N-M1-HP0-ET-NN-D7-NN-FW
R911336100 KSM02.1B-041C-42N-M1-HP0-ET-NN-D7-TO-FW
R911369201 KSM02.1B-041C-42N-M1-HP0-ET-S3-D7-NN-FW
R911375970 KSM02.1B-041C-42N-M1-HP0-ET-S3-D7-TO-FW
R911336101 KSM02.1B-041C-42N-M1-HP2-ET-L3-D7-NN-FW
R911337464 KSM02.1B-041C-42N-M1-HP2-ET-L3-D7-TO-FW
R911337465 KSM02.1B-041C-42N-M1-HP2-ET-NN-D7-NN-FW
R911335541 KSM02.1B-041C-42N-M1-HP2-ET-NN-D7-TO-FW
R911375782 KSM02.1B-041C-42N-M1-HP2-ET-S3-D7-NN-FW
R911385321 KSM02.1B-041C-42N-M3-HG0-ET-L3-D7-ES-FW
R911339811 KSM02.1B-041C-42N-M3-HG0-ET-L3-D7-NN-FW
R911339974 KSM02.1B-041C-42N-M3-HG0-ET-L3-D7-TO-FW
R911337228 KSM02.1B-041C-42N-M3-HG0-ET-NN-D7-NN-FW
R911345656 KSM02.1B-041C-42N-M3-HG0-ET-NN-D7-TO-FW
R911385322 KSM02.1B-041C-42N-M3-HG2-ET-L3-D7-ES-FW
R911341443 KSM02.1B-041C-42N-M3-HG2-ET-L3-D7-NN-FW
R911384458 KSM02.1B-041C-42N-M3-HG2-ET-L3-D7-TO-FW
R911341444 KSM02.1B-041C-42N-M3-HG2-ET-NN-D7-NN-FW
R911342514 KSM02.1B-041C-42N-M3-HP0-ET-L3-D7-NN-FW
R911381148 KSM02.1B-041C-42N-M3-HP0-ET-L3-D7-TO-FW
R911343336 KSM02.1B-041C-42N-M3-HP0-ET-NN-D7-NN-FW
R911381147 KSM02.1B-041C-42N-M3-HP0-ET-NN-D7-TO-FW
R911381072 KSM02.1B-041C-42N-M3-HP2-ET-L3-D7-NN-FW
R911381150 KSM02.1B-041C-42N-M3-HP2-ET-L3-D7-TO-FW
R911343341 KSM02.1B-041C-42N-M3-HP2-ET-NN-D7-NN-FW
R911381149 KSM02.1B-041C-42N-M3-HP2-ET-NN-D7-TO-FW
R911379917 KSM02.1B-041C-42N-S1-HG0-ET-L3-D7-AN-FW
R911335756 KSM02.1B-041C-42N-S1-HG0-ET-L3-D7-NN-FW
R911339623 KSM02.1B-041C-42N-S1-HG0-ET-L3-D7-TO-FW
R911335837 KSM02.1B-041C-42N-S1-HG0-ET-NN-D7-NN-FW
R911343277 KSM02.1B-041C-42N-S1-HG0-ET-NN-D7-TO-FW
R911344039 KSM02.1B-041C-42N-S1-HG0-ET-S3-D7-NN-FW
R911344594 KSM02.1B-041C-42N-S1-HG0-ET-S3-D7-TO-FW
R911378160 KSM02.1B-041C-42N-S1-HG0-ET-SD-D7-NN-FW
R911335757 KSM02.1B-041C-42N-S1-HG2-ET-L3-D7-NN-FW
R911338459 KSM02.1B-041C-42N-S1-HG2-ET-L3-D7-TO-FW
R911335836 KSM02.1B-041C-42N-S1-HG2-ET-NN-D7-NN-FW
R911378742 KSM02.1B-041C-42N-S1-HG2-ET-S3-D7-NN-FW
R911374795 KSM02.1B-041C-42N-S1-HG2-ET-S3-D7-TO-FW
R911336921 KSM02.1B-041C-42N-S1-HP0-ET-L3-D7-NN-FW
R911336920 KSM02.1B-041C-42N-S1-HP0-ET-L3-D7-TO-FW
R911336099 KSM02.1B-041C-42N-S1-HP0-ET-NN-D7-NN-FW
R911380277 KSM02.1B-041C-42N-S1-HP0-ET-S3-D7-NN-FW
R911376424 KSM02.1B-041C-42N-S1-HP2-ET-L3-D7-NN-FW

¹«Ê¾£º Òò¹¤ÒµÒºÑ¹¡¢×Ô¶¯»¯¸÷½ø¿ÚÆ·ÅƱ¸¼þÐͺŷ±¶à£¬Å·ÃÀ²úÆ·¼Û¸ñʵʱ±ä»¯£¬Òò´ËºÜÄÑʵʱ±ê³ö׼ȷ¼Û¸ñ£¬ÇëÒÔÒµÎñԱʵ¼Ê±¨¼Ûµ¥¼Û¸ñΪ׼£¡ ¸øÄú´øÀ´²»±ã¾´ÇëÁ½⡣

 

 

 


¹«Ë¾¼ò½é
²úƷĿ¼
¹©Ó¦ÐÅÏ¢

¹«Ë¾Ãû³Æ£º ÉϺ£Î¤Ã×»úµçÉ豸ÓÐÏÞ¹«Ë¾
µç »°£º 021 31139779 / µË½à
ÊÖ»ú£º 13524123373
µØ Ö·£º ÉϺ£ÊÐÆÖ¶«ÐÂÇø½ðԥ·100ºÅÓíÖݹú¼Ê2ÆÚ2ºÅ907ÊÒ
ÓÊ ±à£º 201206
Ö÷ Ò³£º http://www.weimi.com

¸Ã³§ÉÌÏà¹Ø²úÆ·£º
  • 990-05-XX-01-00 MOD:147202-01±äËÍÆ÷
  •  
  • 990-04-70-01-CN±¾ÌØÀû±äËÍÆ÷
  •  
  • ±¾ÌØÀû±äËÍÆ÷990-04-50-02-00
  •  
  • Bently±äËÍÆ÷990-04-50-01-00
  •  
  • µ¥ÖáÄæ±äÆ÷R911295325 HMS01.1N-W0054-A-07-NNNN
  •  
  • R911295323 HMS01.1N-W0020-A-07-NNNNËÅ·þÇý¶¯Æ÷
  •  
  • R911298372 HCS02.1E-W0070-A-03-NNNN ËÅ·þÇý¶¯Æ÷
  •  
  • ËÅ·þÇý¶¯Æ÷R911298373 HCS02.1E-W0054-A-03-NNNN
  •  
  • R911298371 HCS02.1E-W0012-A-03-NNNN Á¦Ê¿ÀÖËÅ·þÇý¶¯Æ÷
  •  
  • HAS05.1-007-NNR-NN Á¬½ÓÊÊÅäÆ÷
  •  
    ¸ü¶à²úÆ·...
      ¹ØÓÚÎÒÃÇ | ÁªÏµÎÒÃÇ | ¹ã¸æ·þÎñ | ±¾Õ¾¶¯Ì¬ | ÓÑÇéÁ´½Ó | ·¨ÂÉÉùÃ÷ | ·Ç·¨ºÍ²»Á¼ÐÅÏ¢¾Ù±¨  
    ¹¤¿ØÍø¿Í·þÈÈÏߣº0755-86369299
    °æȨËùÓÐ ¹¤¿ØÍø Copyright@ Gkong.com, All Rights Reserved