Ê×Ò³ - ÐÂÎÅ - ÕÐƸ - ÏÂÔØ - ²úÆ· - ³§ÉÌ - ·½°¸ - ÎÄÕª - Çó¹º - Õ¹ÀÀ
Ãâ·Ñ×¢²á µÇ¼ | ¹ã¸æ·þÎñ | ¿Í·þÖÐÐÄ
Öлª¹¤¿ØÍø ¡ú ¹¤¿Ø²úÆ· ¡ú µ¥ÖáÄæ±äÆ÷R911295325 HMS01.1N-W0054-A-07-NNNN
²úÆ·Ãû³Æ£º µ¥ÖáÄæ±äÆ÷R911295325 HMS01.1N-W0054-A-07-NNNN
ÐÍ ºÅ£º R911295325 HMS01.1N-W0054-A-07-NNNN
¼Û ¸ñ£º 0.00
Æ· ÅÆ£º
 
Êղش˲úÆ·     ²é¿´ÊÕ²Ø

Á¦Ê¿ÀÖµ¥ÖáÄæ±äÆ÷R911295325 HMS01.1N-W0054-A-07-NNNN£»ÉϺ£Î¤Ã×»úµçÉ豸ÓÐÏÞ¹«Ë¾Ö÷ÓªÏúÊÛ²úÆ·£¬²úƷʵÅÄ£¬Ô­×°ÕýÆ·£¬¿Í»§ÂòµÄ°²ÐÄ£¬ÓõķÅÐÄ¡£³£ÓòúÆ·ÏÖ»õ¹©Ó¦£¬»¶Ó­ÐÂÀÏ¿Í»§Ñ¯¼Û²É¹º£¡

²úÆ·¼ò½é£º

²©ÊÀÁ¦Ê¿ÀÖ£¨BoschRexroth£©ÊÇÈ«ÇòÁìÏȵĴ«¶¯Óë¿ØÖƼ¼Êõר¼Ò£¬ÖÂÁ¦ÓÚΪ¸÷Àà»úеºÍϵͳÉ豸Ìṩ°²È«¡¢¾«×¼¡¢¸ßЧÒÔ¼°¸ßÐԼ۱ȵĴ«¶¯Óë¿ØÖƼ¼Êõ¡£¹«Ë¾ÈÚºÏÈ«ÇòµÄÓ¦Óþ­Ñ飬ÑÐ ·¢´´ÐµIJúÆ·£¬ÎªÐÐ×ß»úе¡¢»úеӦÓÃÓ빤³Ì¡¢¹¤³§×Ô¶¯»¯¼°¿ÉÔÙÉúÄÜԴÿһ¸öϸ·ÖÊг¡µÄ¿Í»§Á¿Éí¶¨ÖÆϵͳ½â¾ö·½°¸¼°·þÎñ¡£

²©ÊÀÁ¦Ê¿ÀÖͬʱΪ¿Í»§Ìṩ¸÷ÖÖÒº ѹ¡¢µç×Ó´«¶¯Óë¿ØÖÆ¡¢Æø¶¯¡¢³ÝÂÖ¡¢ÏßÐÔ´«¶¯¼°×é×°¼¼Êõ¡£¹«Ë¾ÒµÎñ±é¼°È«Çò80¶à¸ö¹ú¼Ò£¬ÓµÓÐ37£¬500¶àÃûרҵԱ¹¤£¬2012ÄêÈ«ÇòµÄÏúÊÛ¶î½ü65ÒÚÅ·Ôª¡£

¹¤³ÌÉè¼Æ
ÖÐÑëÈí¼þ¹¤¾ßÊÇÔÚÉ豸Õû¸öÉúÃüÖÜÆÚÄÚ¶Ô²»Í¬Ó¦ÓýøÐиßЧ¹æ»®¡¢±à³Ì¡¢µ÷ÊÔºÍÕï¶ÏµÄ IndraWorks ¹¤³Ì¿ò¼Ü¡£
¹¦Äܹ¤¾ß°üͨ¹ý¼¼ÊõÐͽâ¾ö·½°¸Îª±ê×¼ PLC ¹¤³Ì¿ò¼Ü IndraWorksÌṩ¹¦ÄÜÀ©Õ¹·þÎñ¡£ÕâЩ¹¦ÄÜ°ü¼ÓËÙÁ˸´ÔÓ»úÆ÷¹ý³ÌµÄÖ´ÐУ¬Í¨¹ý¸½¼ÓµÄ¹¤³Ì½Ó¿ÚÓÅ»¯ÁË»úÆ÷ÖÆÔì¹ý³ÌÖеÄÏîÄ¿¹¤×÷Á÷£¬»òͨ¹ý¸ß¼¶»úÆ÷¹¦ÄܵľùÔȼ¯³ÉÌá¸ßÁËÉú²úÁ¦¡£

Èí¼þ¹¤¾ß
ÊÊÓÃÓÚÕû¸ö¹¤³ÌÁ÷³ÌµÄ¸÷ÖÖ¹¤¾ß
-¿ìËÙ¹¤³ÌÓëÖ¸µ¼¹¤×÷Á÷³ÌÍêÃÀ½áºÏ
-ÓÃÓÚËùÓÐ PLC º¯ÊýµÄÊæÊʱà³Ì»·¾³
-×ÛºÏÈí¼þ¿â·ûºÏ IEC 61131-3 ºÍ PLCopen
-¼òÒ×µÄÓû§½çÃ棬°üÀ¨±êÌâ¡¢Óû§Çø¡¢Óû§¹ÜÀí
-¿ØÖƺÍÇý¶¯ÐÅÏ¢µÄ¼¯³ÉÕï¶Ï
ºËÐÄÈí¼þ¹¤¾ßΪ IndraWorks engineering framework£¬ËüÓÃÓÚÔÚÉ豸µÄÕû¸ö²úÆ·ÉúÃüÖÜÆÚÖнøÐÐÓÐЧ¹æ»®¡¢±à³Ì¡¢µ÷ÊÔºÍÕï¶Ï²»Í¬Ó¦ÓóÌÐò¡£
ÆäËû¹¤¾ß°üÀ¨£ºÓÃÓÚ¿ÉÊÓ»¯Éè¼ÆµÄ WinStudio¡¢ÓÃÓÚ°²È«¿ØÖÆÅäÖÃÓë±à³ÌµÄ SafeLogic Designer¡¢»òÓÃÓÚ¿ØÖÆÖÁ IT ¼¶±ðÁ¬½ÓµÄ WebConnector ºÍ¸ßÐÔÄÜ×éºÏ¹¤³Ì¹¤¾ß¡£

¹¦Äܹ¤¾ß°ü
±ê×¼¹¦ÄÜÀ©Õ¹¹¤¾ß
-¸´ÔÓÈÎÎñµÄ¼ÓËÙÖ´ÐÐ
-¸ß¼¶»úÆ÷¹¦ÄܵÄÎ޷켯³É
-ÓÃÓÚ¼ÓËÙ±à³ÌµÄÀ©Õ¹¿â
-¶îÍâµÄ¹¤³Ì½Ó¿Úʹ¹¤×÷Á÷µÃµ½ÁËÓÅ»¯
-ͨ¹ý°æ±¾¿ØÖÆʵÏÖÄ£¿é»¯¹¤³Ì
¹¦Äܹ¤¾ß°üͨ¹ý¼¼ÊõÐͽâ¾ö·½°¸Îª±ê×¼ PLC ¹¤³Ì¿ò¼Ü IndraWorksÌṩ¹¦ÄÜÀ©Õ¹·þÎñ¡£ËùÒÔ£¬ÀýÈ磬“ͨÓÃÓ¦ÓÃÄ£°å£¨GAT£©”ÌṩÁË×¼±¸ºÃµÄ¿ò¼ÜÓ¦ÓóÌÐò¡£“´¦À픹¦Äܹ¤¾ß°üÌṩÁËÔ¤ÏÈÅäÖúõĵѿ¨¶ûϵͳ½â¾ö·½°¸£»“ÍŶӹ¤³Ì”¹¦Äܹ¤¾ß°üΪ¹¤³ÌÏîÄ¿ÌṩÁË°æ±¾¹ÜÀíϵͳ¡£

ͨ¹ý“ͨÓÃÓ¦ÓÃÄ£°å£¨GAT£©”¹¦Äܹ¤¾ß°ü£¬Äú¿ÉÒÔΪ¿ÉÖØÓÃÓ¦ÓóÌÐò´´½¨»ùÓÚÄ£°åµÄÄ£¿é»¯»úÆ÷Èí¼þ¡£ÔÚ IndraWorks Engineering ÖеÄͨÓÃÓ¦ÓÃÄ£°åÖÐÖ±½Ó´´½¨ÄúµÄÏîÄ¿£¬²¢Í¨¹ý×¼±¸ºÃµÄ¿ò¼ÜÓ¦Ó㬴ÓʾÀý³ÌÐò¡¢Ó¦ÓÃÄ£°å¡¢»òÍêÕûÄ£°åÖнøÐÐÑ¡Ôñ¡£×´Ì¬»ú¡¢²Ù×÷ģʽ¡¢Êý¾Ý½Ó¿ÚºÍµäÐÍÐòÁÐÒѾ­ÍêÈ«¼¯³ÉÔÚͨÓÃÓ¦ÓÃÄ£°å£¨GAT£©ÖС£Äú¿ÉÒÔͨ¹ýÖ±¹ÛµÄ²Ù×÷Ïòµ¼À´´´½¨Ìض¨Ó¦ÓõÄÀ©Õ¹¡£¸ÃÏòµ¼½«Ö±½ÓÒýµ¼Äú½øÈ뿪·Å IEC 61131-3 ÏîÄ¿µÄλÖã¬Óû§´úÂë¾ÍÔÚÕâÀïÊäÈë¡£ÕâÖÖ·½·¨ÒÔ¼°»úÆ÷ÏîÄ¿µÄÎȶ¨Ä£¿é»¯½á¹¹£¬²»µ«¼Ó¿ìÁËÐÂÏîÄ¿µÄ´´½¨£¬»¹ÒòºóÐøµ÷ÕûºÍÔöÇ¿Ìá¸ßÁËÈí¼þÖÊÁ¿ºÍ¹¤³ÌЧÂÊ¡£Ó봫ͳµÄ¾²Ì¬±à³ÌÄ£°åÏà±È£¬Äú¿ÉÒÔʹÓÃÏòµ¼À´ÎªËùÐèÓ¦ÓÃÉ趨ÀíÏëµÄ³ÌÐò´óС¡£PLC Ó¦Óö¯Ì¬Ôö³¤£¬Òò´Ë¼´Ê¹ÔÚ¶à´Î¸ü¸ÄÖ®ºó£¬³ÌÐò½á¹¹ÈÔÈ»¿ÉÒÔͨ¹ý×Ô¶¯´úÂëÉú³ÉµÄ·½Ê½±£Áô¡£

½èÖúÓÚ“ÍŶӹ¤³Ì”¹¦Äܹ¤¾ß°ü£¬Äú¿ÉÒÔ½«°æ±¾¹ÜÀíϵͳ¼¯³Éµ½ IndraWorks Engineering ÖС£Í¨¹ý¶Ô¸öÈË»òÍŶӽøÐм¯³ÉÊý¾Ý¹ÜÀí£¬°æ±¾»¯µÄÏîÄ¿Ìá¸ßÁ˹¤³Ì¹¤×÷Á÷µÄЧÂÊ¡£ÏîÄ¿ºÍÊý¾Ý¹ÜÀíµÄ¹ã·º¹¦ÄÜÓÐÖúÓÚ¸ú×ÙÏîÄ¿±ä»¯£¬²¢Ê¹Ó¦ÓóÌÐòµÄÏà¹Ø¹¤×÷ÄÜÔÚÄÚ²¿ºÍµ÷ÊÔ¹ý³ÌÖв¢ÐÐÖ´ÐС£

ͨ¹ýSafetyManager ¹¦Äܹ¤¾ß°ü´´½¨°²È«Ó¦ÓóÌÐò¡£¸ù¾Ý PLCopen °²È«¹æ·¶µÄÔ­Ôò½øÐбà³Ì¡£¸Ã·½·¨Ö¼ÔÚÉè¼ÆÓëÀëÉ¢°²È«¿ª¹Ø×°Öò¼ÏßÀàËƵıà³Ì¡£¾­¹ýÈÏÖ¤µÄ¹¦ÄÜÄ£¿éÈ¡´úÁË¿ª¹ØÉ豸£¬¶øÀëÉ¢²¼Ïß±»¹¦ÄÜÄ£¿éµÄͼÐÎÁ¬½Ó£¨±à³Ì£©ËùÈ¡´ú¡£

Robot Control ¹¦Äܹ¤¾ß°üÌṩÁË´óÁ¿Ô¤¶¨ÒåµÄÔ˶¯ºÍת»»£¬ÒԱ㰴ҪÇóÓëÕûºÏÔÚÏîÄ¿Öеıê×¼»¯»úÆ÷ÈËÒ»ÆðʹÓá£ÅäÖúͲÎÊý»¯µÄ¶Ô»°¿òÓÐÖúÓÚÉèÖûúÆ÷ÈË¡£¸÷»ú¹¹Í¨¹ý PLC Ä£¿éÓë¸÷×ÔµÄת»»¼¯³Éµ½¿ØÖÆϵͳÖС£×ۺϹ¦ÄÜ¿âÔÊÐí´øÍêÕûͬ²½´øµÄ¸´ÔÓÔ˶¯¡£Í¨¹ý PLCopenÒÔ¼°ÓÃÓڸ߼¶±à³ÌÓïÑÔµÄÔ˶¯Ñ§½Ó¿ÚºÍ¿ª·ÅºËÐĽӿڣ¬ÎªÓû§¿ª·¢Ó¦ÓôøÀ´Á˼«´óµÄÁé»îÐÔ¡£

ÓÃÓÚËùÓмòµ¥¼°µÑ¿¨¶ûÔ˶¯ÈÎÎñµÄÔ¤ÅäÖÃϵͳ½â¾ö·½°¸“IndraMotion for Handling”Ϊ×Ô¶¯Ä£Ê½ºÍÊÖ¶¯Ä£Ê½¶¼ÌṩÁË×ۺϹ¦ÄܺͿÉÊÓ»¯Ð§¹û¡£¶Ô»°¿òÒýµ¼ÐÍÃüÁîÑ¡Ôñ»ò Intellisense ¸¨ÖúʽÃüÁîÑ¡Ôñ£¬È·±£ÁË¿ÉÖ±¹Û¡¢¼òµ¥µØ¶ÔÍâΧÉ豸µÄÔ˶¯ºÍÐźŽøÐбà³Ì¡£Õâ¾ÍÊÇÓ¦ÓóÌÐòµÄÀíÏë¿ØÖÆÊֶΣ¬È磺ȡ·Å×°Öá¢Ö±Á¢Ãżܡ¢Ê®×Ö¹¤×÷̨¡¢Ö÷±Û¼°Á¢ÌåÃżܵȡ£


IndraControl XM ϵÁвúÆ·µÄǶÈëʽ¿ØÖÆÆ÷£¬ÒÔ¼° IndraControl S20 ϵÁвúÆ·µÄÊäÈëÊä³ö Ä£¿é£¬¹²Í¬¹¹³ÉÁË IoT Íø¹ØµÄ¿ÉÀ©Õ¹Ó²¼þƽ̨¡£
ͨ¹ý¼¯³ÉÈí¼þÓ¦Óã¬¿É¶Ô IoT Íø¹Ø½øÐÐÁé»îÇáËɵĵ÷Õû£º
-ÒDZí°åÓ¦Óà - ¼¯³ÉµÄÍøÒ³½çÃ棬¿ÉʵÏÖ¿ìËÙ·½±ãµÄÅäÖúʹ¦Àí£¬ÎÞÐèÈκαà³Ì
-É豸ӦÓà - ÓÃÓÚÑ¡ÔñºÍÅäÖô«¸ÐÆ÷
-´¦ÀíÓ¦Óà - ÓÃÓÚ´¦ÀíÊý¾ÝºÍ²¢½«Êý¾Ý´«Êäµ½¸ü¸ß¼¶±ðµÄϵͳ


IndraControl L ÊǾ­¹ýʵ¼ùÑéÖ¤µÄ¿ØÖÆƽ̨£¬ËüµÄÄÚÖÃÐÎʽ±ãÓÚ°²×°ÔÚ DIN µ¼¹ìÉÏ¡£¸Ãƽ̨ÒÔ¾­¼Ãʵ»Ý£¬¼¯³ÉºÍ͸Ã÷µÄ½â¾ö·½°¸ÌṩËùÓÐ×Ô¶¯»¯¹¦ÄÜ¡£¹¦ÄÜÇ¿´óµÄCPU¿ìËÙÐźŴ¦ÀíºÍ¾ß±¸¸ßÐÔÄÜ ¶à¿É¼¯ÖпØÖÆ 64 ¸ùÖᣬͬʱ´ïµ½¸ßµÄͬ²½ÐÔºÍ׼ȷµÄÐźž«¶È¡£

ÓÃÓÚ NYCe 4000 µÄÓ¦ÓóÌÐòÈí¼þ¾ßÓпª·Åʽ¼Ü¹¹£¬Ê¹Óû§Äܹ»·ÃÎÊÓÃÓÚÔ˶¯¡¢ÊäÈë/Êä³ö´¦Àí¡¢´íÎó´¦ÀíºÍͬ²½µÄËùÓм¯³É¹¦ÄÜ¡£¸ÃÓ¦ÓóÌÐòÈí¼þÔÊÐí·ÃÎÊËùÓÐÅäÖú͵÷Õû²ÎÊý£¬²¢Ìṩ¹Ì¼þ/Gateware ÏÂÔع¦ÄÜ£¬ÒÔ±ã½øÐÐÏÖ³¡Éý¼¶¡£¸ÃÓ¦ÓóÌÐòÈí¼þ²ÉÓà C/C++ ±à³Ì£¬Í¨³£ÔÚÖ÷ PC ÉÏÔËÐС£ÎªÔËÐÐʵʱ³ÌÐò»òʵÏÖ¶ÀÁ¢²Ù×÷£¬ÄúÒ²¿ÉÒÔÔÚÔ˶¯¿ØÖÆ×°ÖÃÉÏÖ±½ÓÔËÐÐÓû§Èí¼þ¡£Õâ³ÆΪÐòÁбà³Ì¡£ÕâÓë PC ÉϵÄÓ¦ÓóÌÐò±à³Ì·Ç³£ÀàËÆ£»±à³ÌÒ²²ÉÓà C ÓïÑÔ½øÐС£Óû§¿ÉÒÔ¶ÔÏàÓ¦µÄÈí¼þ×é¼þ½øÐе÷Õû£¬´Ó¶ø¶Ô¿ØÖÆÆ÷¹Ì¼þÖеĻúÆ÷רÓÃÁ÷³Ì½øÐбà³Ì¡£¿É±à³ÌÔª¼þµ¥Ôª°üÀ¨£º
-UDSX£º¼¯³É¿ØÖƳÌÐò£¨C ±à³Ì£©
-UDC£ºÃ¿¸öÖáµÄ±ê×¼µ÷Õû

Á¦Ê¿ÀÖREXROTH¹¦ÄÜÄ£¿éRTÒÔÌ«ÍøºÍPROFIBUS
R911170832 CFL01.1-TP
RTÒÔÌ«Íø£¨PROFINET RT¡¢ÒÔÌ«Íø/IP¡¢ÒÔÌ«Íø TCP/IP£©
PROFIBUS DP
CML¿ØÖÆÆ÷µÄÄ£¿é»¯À©Õ¹
·À»¤µÈ¼¶IP20
ͨ¹ý¸½¼ÓµÄ¼¼ÊõÌØÐÔÀ©Õ¹ÁË¿ØÖƹ¦ÄÜ
À©Õ¹ÁËÓëÆäËû½Ó¿ÚµÄÁ¬½Ó
½«±ê×¼¿ØÖÆÀ©Õ¹µ½SafeLogic°²È«¿ØÖÆÆ÷
¹¦ÄÜÄ£¿é¾ßÓÐʵʱÒÔÌ«ÍøºÍPROFIBUS DPÖ÷É豸»òPROFIBUS DP´ÓÉ豸¹¦ÄÜ¡£¸ù¾ÝÅäÖ㬿ÉÒÔÔÚÄ£¿éÉϽ«²»Í¬µÄÒÔÌ«ÍøЭÒéÓëPROFIBUS DPÒ»ÆðÖ´ÐС£ÒÔÌ«ÍøЭÒé¿ÉÒÔÊÇPROFINET RT¡¢EtherNet/IP»ò±ê×¼TCP/IPµÈ¡£
»·¾³Î¶ȣ¨ÔËÐÐʱ£©  +5 ... +55¡æ
ÈÝÐíµÄÏà¶Ôʪ¶È£¨ÔËÐÐʱ£©  5 % ... 95 %
¹¦ÂÊÏûºÄ  1.65W

Á¦Ê¿ÀÖREXROTH±äƵÆ÷
HCS02 - µ¥Öáת»»Æ÷
1.5 kW ... 11 kW ¹¦ÂÊ·¶Î§
12 A ... 70 A µçÁ÷
200 V ... 500 V Ö±Á÷µçÔ´
2.5x ¹ýÔØÈÝÁ¿
½ô´ÕÐÍÉè¼Æ£¬ÊʺÏÓÚµ¥ÖáÓ¦ÓÃ
IndraDrive C£¨HCS02£©×ª»»Æ÷º­¸ÇÁËÖй¦ÂÊ·¶Î§kW¡£´Ë×°ÖÃÉèÖÃÁËÒ»¸ö¿ØÖƵ¥Ôª²Û£¬Óи÷ÖÖ½Ó¿Ú£¬ÓÃÓÚÁ¬½Ó×Ô¶¯»¯»·¾³£¬ÊÊÓÃÓÚ±àÂëÆ÷ϵͳ¡¢°²È«¼¼Êõ¡¢ºÍÆäËüÊý×Ö¼°Ä£ÄâÐźŵȡ£

Á¦Ê¿ÀÖREXROTHÄ£¿é»¯×ª»»Æ÷
HMS01 µ¥ÖáÄæ±äÆ÷
5.5 kW ... 132 kW ¹¦ÂÊ·¶Î§
12.1 A ... 250 A Á¬ÐøµçÁ÷
12 A ... 350 A ´óµçÁ÷
540 V ... 750 V Ö±Á÷ Ïß·µçѹ
·À»¤µÈ¼¶IP20
HMS01 µ¥ÖáÄæ±äÆ÷ÓÉÖ±Á÷¹©µç£¬²¢Í¨¹ýÖ±Á÷Éú³É±äƵ±ä·ùµÄÊܿؽ»Á÷Êä³öµçѹ£¬ÓÃÓÚÔËÐеç»ú¡£´Ë×°ÖÃÉèÖÃÁËÒ»¸öµ¥Öá¿ØÖƵ¥Ôª²Û£¬Óи÷ÖÖ½Ó¿Ú£¬ÓÃÓÚÁ¬½Ó×Ô¶¯»¯»·¾³£¬ÊÊÓÃÓÚ±àÂëÆ÷ϵͳ¡¢°²È«¼¼Êõ¡¢ºÍÆäËüÊý×Ö¼°Ä£ÄâÐźŵȡ£ÔÚ¶àÖáÓ¦ÓÃÖУ¬Äæ±äÆ÷ͨ¹ý HMV01 »ò HMU05 µçÔ´É豸µÄÖ±Á÷×ÜÏß¹©µç¡£¶ÔÓÚ½ÏСµÄÖá°ü£¬ÒÔ¼°¾ßÓÐÏàÓ¦¶¯Á¦´¢´æµÄ HCS£¬Ò²¿ÉÒÔÓÉ HCS ת»»Æ÷µÄÖ±Á÷×ÜÏß¹©µç¡£

 

Ö÷ÓªÐͺţº

Á¦Ê¿ÀÖREXROTHµ¥ÖáÄæ±äÆ÷HMS01
R911305196 AIR GUIDE PLATE HMS01.1-W0150 RE
R911294927 ANSCHLUSSBLOCK HMD/HMS01.1
R911295317 ANSCHLUSSBLOCK HMS01.1-W0150
R911326701 BASISGERAET HMS01.1N-W0110-A-07-NNNN
R911324837 BUS BAR HMS01.1-W0150 L+ RE &
R911324836 BUS BAR HMS01.1-W0150 L- RE &
R911294930 CABLE PASSAGE HMD/HMS01.1 X1
R911339055 DOK-INDRV*-HMS01******-ITRS-DE-P
R911295665 FRONT PANEL HMS01.1 DSUB 09POL.-&
R911295323 HMS01.1N-W0020-A-07-NNNN
R911326671 HMS01.1N-W0020-A-07-NNNN-AA
R911295324 HMS01.1N-W0036-A-07-NNNN
R911326672 HMS01.1N-W0036-A-07-NNNN-AA
R911295325 HMS01.1N-W0054-A-07-NNNN
R911326673 HMS01.1N-W0054-A-07-NNNN-AA
R911295326 HMS01.1N-W0070-A-07-NNNN
R911326674 HMS01.1N-W0070-A-07-NNNN-AA
R911310462 HMS01.1N-W0110-A-07-NNNN
R911326675 HMS01.1N-W0110-A-07-NNNN-AA
R911295327 HMS01.1N-W0140-A-07-NNNN
R911297164 HMS01.1N-W0150-A-07-NNNN
R911326676 HMS01.1N-W0150-A-07-NNNN-AA
R911295328 HMS01.1N-W0210-A-07-NNNN
R911326677 HMS01.1N-W0210-A-07-NNNN-AA
R911338644 HMS01.1N-W0300-A-07-NNNN
R911317351 HMS01.1N-W0350-A-07-NNNN
R911326678 HMS01.1N-W0350-A-07-NNNN-AA
R911329511 HOUSING HMS01.1-W0210
R911305033 INDRADRIVE HMS01
R911305175 INSULATING FOIL HMS01.1-W0150 SCHIEN&
R911326986 KEDRIVE D6-HMS01
3¡¢Á¦Ê¿ÀÖREXROTHË«ÖáÄæ±äÆ÷HMD01
R911294929 BGR DRUCKKAMMER HMD01.1-W0020
R911306439 HMD01.1N-W0012-A-07-NNNN
R911326665 HMD01.1N-W0012-A-07-NNNN-AA
R911295322 HMD01.1N-W0020-A-07-NNNN
R911326666 HMD01.1N-W0020-A-07-NNNN-AA
R911298766 HMD01.1N-W0036-A-07-NNNN
R911326667 HMD01.1N-W0036-A-07-NNNN-AA
R911305062 INDRADRIVE HMD01
R911329632 KEDRIVE D6-HMD01
4¡¢Á¦Ê¿ÀÖREXROTHµçÔ´É豸HMV02
R911339069 DOK-INDRV*-HMV02******-ITRS-DE-P
R911322051 HMV02.1E-F0025-A-07-NNBN
R911321180 HMV02.1E-F0075-A-07-NNBN
R911321588 HMV02.1R-F0150-A-07-NNNN
R911332495 HMV02.1R-W0015-A-07-FNN2
R911388401 HMV02.1R-W0015-A-07-FNN6
R911309080 HMV02.1R-W0015-A-07-NNNN
R911326670 HMV02.1R-W0015-A-07-NNNN-AA
5¡¢Á¦Ê¿ÀÖREXROTHµ¥ÖáÄæ±äÆ÷HMS02
R911322220 HMS02.1N-F0028-A-07-NNNN
R911325238 HMS02.1N-F0054-A-07-NNNN
R911321332 HMS02.1N-F0070-A-07-NNNN
R911321331 HMS02.1N-F0110-A-07-NNNN
R911323458 HMS02.1N-F0110-A-07-S003
R911324527 HMS02.1N-F0150-A-07-NNNN
R911324528 HMS02.1N-F0210-A-07-NNNN
R911309078 HMS02.1N-W0028-A-07-NNNN
R911326668 HMS02.1N-W0028-A-07-NNNN-AA
R911309079 HMS02.1N-W0054-A-07-NNNN
R911326669 HMS02.1N-W0054-A-07-NNNN-AA
R900897432 HOUSING MH2M6-15L100/VBHMS02D
R911311669 INDRADRIVE HMS02
6¡¢Á¦Ê¿ÀÖREXROTHµçÔ´É豸/Äæ±äÆ÷HMU05
R911345470 HMU05.1N-F0120-0290-N-A4-D7-N1N-NNNN
R911380155 HMU05.1N-F0120-0290-N-A4-D7-P11-MNNN
R911346484 HMU05.1N-F0120-0290-N-A4-D7-P11-NNNN
R911380154 HMU05.1N-F0120-0290-N-A4-D7-P1B-MNNN
R911346483 HMU05.1N-F0120-0290-N-A4-D7-P1B-NNNN
R911380156 HMU05.1N-F0120-0290-N-A4-D7-PB1-MNNN
R911346485 HMU05.1N-F0120-0290-N-A4-D7-PB1-NNNN
R911380153 HMU05.1N-F0120-0290-N-A4-D7-PBB-MNNN
R911346482 HMU05.1N-F0120-0290-N-A4-D7-PBB-NNNN
R911379651 HMU05.1N-F0140-0210-N-A5-11-P11-MNNN
R911379650 HMU05.1N-F0140-0210-N-A5-11-P1B-MNNN
R911379652 HMU05.1N-F0140-0210-N-A5-11-PB1-MNNN
R911379649 HMU05.1N-F0140-0210-N-A5-11-PBB-MNNN
R911345469 HMU05.1N-F0140-0350-N-A4-D7-N1N-NNNN
R911382640 HMU05.1N-F0140-0350-N-A4-D7-N1N-NS01
R911380159 HMU05.1N-F0140-0350-N-A4-D7-P11-MNNN
R911346488 HMU05.1N-F0140-0350-N-A4-D7-P11-NNNN
R911380158 HMU05.1N-F0140-0350-N-A4-D7-P1B-MNNN
R911346487 HMU05.1N-F0140-0350-N-A4-D7-P1B-NNNN
R911380160 HMU05.1N-F0140-0350-N-A4-D7-PB1-MNNN
R911346489 HMU05.1N-F0140-0350-N-A4-D7-PB1-NNNN
R911380157 HMU05.1N-F0140-0350-N-A4-D7-PBB-MNNN
R911346486 HMU05.1N-F0140-0350-N-A4-D7-PBB-NNNN
R911379647 HMU05.1N-F0170-0250-N-A5-11-P11-MNNN
R911376917 HMU05.1N-F0170-0250-N-A5-11-P11-NNNN
R911376916 HMU05.1N-F0170-0250-N-A5-11-P1B-MNNN
R911379648 HMU05.1N-F0170-0250-N-A5-11-PB1-MNNN
R911376918 HMU05.1N-F0170-0250-N-A5-11-PB1-NNNN
R911379646 HMU05.1N-F0170-0250-N-A5-11-PBB-MNNN
R911376915 HMU05.1N-F0170-0250-N-A5-11-PBB-NNNN
R911345468 HMU05.1N-F0170-0430-N-A4-D7-N1N-NNNN
R911382641 HMU05.1N-F0170-0430-N-A4-D7-N1N-NS01
R911380163 HMU05.1N-F0170-0430-N-A4-D7-P11-MNNN
R911346492 HMU05.1N-F0170-0430-N-A4-D7-P11-NNNN
R911380162 HMU05.1N-F0170-0430-N-A4-D7-P1B-MNNN
R911346491 HMU05.1N-F0170-0430-N-A4-D7-P1B-NNNN
R911380164 HMU05.1N-F0170-0430-N-A4-D7-PB1-MNNN
R911346493 HMU05.1N-F0170-0430-N-A4-D7-PB1-NNNN
R911380161 HMU05.1N-F0170-0430-N-A4-D7-PBB-MNNN
R911346490 HMU05.1N-F0170-0430-N-A4-D7-PBB-NNNN
R911379644 HMU05.1N-F0220-0300-N-A5-11-P11-MNNN
R911379643 HMU05.1N-F0220-0300-N-A5-11-P1B-MNNN
R911379645 HMU05.1N-F0220-0300-N-A5-11-PB1-MNNN
R911379642 HMU05.1N-F0220-0300-N-A5-11-PBB-MNNN
R911345467 HMU05.1N-F0220-0510-N-A4-D7-N1N-NNNN
R911382642 HMU05.1N-F0220-0510-N-A4-D7-N1N-NS01
R911380167 HMU05.1N-F0220-0510-N-A4-D7-P11-MNNN
R911346496 HMU05.1N-F0220-0510-N-A4-D7-P11-NNNN
R911380166 HMU05.1N-F0220-0510-N-A4-D7-P1B-MNNN
R911346495 HMU05.1N-F0220-0510-N-A4-D7-P1B-NNNN
R911380168 HMU05.1N-F0220-0510-N-A4-D7-PB1-MNNN
R911346498 HMU05.1N-F0220-0510-N-A4-D7-PB1-NNNN
R911380165 HMU05.1N-F0220-0510-N-A4-D7-PBB-MNNN
R911346494 HMU05.1N-F0220-0510-N-A4-D7-PBB-NNNN
R911379640 HMU05.1N-F0270-0370-N-A5-11-P11-MNNN
R911379639 HMU05.1N-F0270-0370-N-A5-11-P1B-MNNN
R911379641 HMU05.1N-F0270-0370-N-A5-11-PB1-MNNN
R911379638 HMU05.1N-F0270-0370-N-A5-11-PBB-MNNN
R911345466 HMU05.1N-F0270-0660-N-A4-D7-N1N-NNNN
R911382643 HMU05.1N-F0270-0660-N-A4-D7-N1N-NS01
R911380171 HMU05.1N-F0270-0660-N-A4-D7-P11-MNNN
R911346502 HMU05.1N-F0270-0660-N-A4-D7-P11-NNNN
R911380170 HMU05.1N-F0270-0660-N-A4-D7-P1B-MNNN
R911346501 HMU05.1N-F0270-0660-N-A4-D7-P1B-NNNN
R911380172 HMU05.1N-F0270-0660-N-A4-D7-PB1-MNNN
R911346503 HMU05.1N-F0270-0660-N-A4-D7-PB1-NNNN
R911380169 HMU05.1N-F0270-0660-N-A4-D7-PBB-MNNN
R911346499 HMU05.1N-F0270-0660-N-A4-D7-PBB-NNNN
R911380175 HMU05.1N-F0340-0820-N-A4-D7-P11-MNNN
R911344886 HMU05.1N-F0340-0820-N-A4-D7-P11-NNNN
R911382644 HMU05.1N-F0340-0820-N-A4-D7-P11-NS01
R911380174 HMU05.1N-F0340-0820-N-A4-D7-P1B-MNNN
R911344885 HMU05.1N-F0340-0820-N-A4-D7-P1B-NNNN
R911380176 HMU05.1N-F0340-0820-N-A4-D7-PB1-MNNN
R911344888 HMU05.1N-F0340-0820-N-A4-D7-PB1-NNNN
R911382645 HMU05.1N-F0340-0820-N-A4-D7-PB1-NS01
R911380173 HMU05.1N-F0340-0820-N-A4-D7-PBB-MNNN
R911344883 HMU05.1N-F0340-0820-N-A4-D7-PBB-NNNN
R911382646 HMU05.1N-F0340-0820-N-A4-D7-PBB-NS01
R911379636 HMU05.1N-F0400-0600-N-A5-11-P11-MNNN
R911376921 HMU05.1N-F0400-0600-N-A5-11-P11-NNNN
R911376920 HMU05.1N-F0400-0600-N-A5-11-P1B-MNNN
R911379637 HMU05.1N-F0400-0600-N-A5-11-PB1-MNNN
R911376922 HMU05.1N-F0400-0600-N-A5-11-PB1-NNNN
R911379635 HMU05.1N-F0400-0600-N-A5-11-PBB-MNNN
R911376919 HMU05.1N-F0400-0600-N-A5-11-PBB-NNNN
R911380179 HMU05.1N-F0430-1040-N-A4-D7-P11-MNNN
R911345460 HMU05.1N-F0430-1040-N-A4-D7-P11-NNNN
R911380178 HMU05.1N-F0430-1040-N-A4-D7-P1B-MNNN
R911345459 HMU05.1N-F0430-1040-N-A4-D7-P1B-NNNN
R911380180 HMU05.1N-F0430-1040-N-A4-D7-PB1-MNNN
R911345461 HMU05.1N-F0430-1040-N-A4-D7-PB1-NNNN
R911380177 HMU05.1N-F0430-1040-N-A4-D7-PBB-MNNN
R911345458 HMU05.1N-F0430-1040-N-A4-D7-PBB-NNNN
R911379633 HMU05.1N-F0540-0750-N-A5-11-P11-MNNN
R911379632 HMU05.1N-F0540-0750-N-A5-11-P1B-MNNN
R911379634 HMU05.1N-F0540-0750-N-A5-11-PB1-MNNN
R911379631 HMU05.1N-F0540-0750-N-A5-11-PBB-MNNN
R911380183 HMU05.1N-F0540-1300-N-A4-D7-P11-MNNN
R911345456 HMU05.1N-F0540-1300-N-A4-D7-P11-NNNN
R911380182 HMU05.1N-F0540-1300-N-A4-D7-P1B-MNNN
R911345455 HMU05.1N-F0540-1300-N-A4-D7-P1B-NNNN
R911380184 HMU05.1N-F0540-1300-N-A4-D7-PB1-MNNN
R911345457 HMU05.1N-F0540-1300-N-A4-D7-PB1-NNNN
R911380181 HMU05.1N-F0540-1300-N-A4-D7-PBB-MNNN
R911345454 HMU05.1N-F0540-1300-N-A4-D7-PBB-NNNN
R911345464 HMU05.1N-F0680-1690-N-A4-D7-P11-NNNN
R911345463 HMU05.1N-F0680-1690-N-A4-D7-P1B-NNNN
R911345465 HMU05.1N-F0680-1690-N-A4-D7-PB1-NNNN
R911345462 HMU05.1N-F0680-1690-N-A4-D7-PBB-NNNN
R911386313 HMU05.1N-W0140-0350-N-A4-D7-P1B-NNNN
R911386314 HMU05.1N-W0220-0510-N-A4-D7-P1B-NNNN
R911386315 HMU05.1N-W0270-0660-N-A4-D7-P11-NNNN
R911386316 HMU05.1N-W0270-0660-N-A4-D7-P1B-NNNN
R911386317 HMU05.1N-W0270-0660-N-A4-D7-PB1-NNNN
R911386318 HMU05.1N-W0340-0820-N-A4-D7-P11-NNNN
R911387086 HMU05.1N-W0340-0820-N-A4-D7-P11-NS02
R911387087 HMU05.1N-W0340-0820-N-A4-D7-P1B-NS02
R911386319 HMU05.1N-W0340-0820-N-A4-D7-PB1-NNNN
R911387088 HMU05.1N-W0340-0820-N-A4-D7-PB1-NS02
R911387089 HMU05.1N-W0340-0820-N-A4-D7-PBB-NS02
R911340885 INDRADRIVE ML HMU05.1 SET CONFIG
¢è¡¢Á¦Ê¿ÀÖREXROTH¿ØÖƵ¥Ôª
1¡¢Á¦Ê¿ÀÖREXROTHµ¥Öá¿ØÖƵ¥Ôª£¨¾­¼ÃÐÍ£©CSE02
R911372077 CSE02.1A-S3-EC-EP-L3-NN-FW
R911372078 CSE02.1A-S3-EC-EP-NN-NN-FW
R911339030 CSE02.1A-S3-EC-NN-L3-NN-FW
R911383410 CSE02.1A-S3-EC-NN-L3-NN-NW
R911383835 CSE02.1A-S3-EC-NN-NN-NN-AW
R911338328 CSE02.1A-S3-EC-NN-NN-NN-FW
7472A04446 HVBS 05.CSE 0210.3.V.G.
7472A03940 HVBS 08.CSE 0240.2.H.G.

¹«Ê¾£º Òò¹¤ÒµÒºÑ¹¡¢×Ô¶¯»¯¸÷½ø¿ÚÆ·ÅƱ¸¼þÐͺŷ±¶à£¬Å·ÃÀ²úÆ·¼Û¸ñʵʱ±ä»¯£¬Òò´ËºÜÄÑʵʱ±ê³ö׼ȷ¼Û¸ñ£¬ÇëÒÔÒµÎñԱʵ¼Ê±¨¼Ûµ¥¼Û¸ñΪ׼£¡ ¸øÄú´øÀ´²»±ã¾´ÇëÁ½⡣

 

 


¹«Ë¾¼ò½é
²úƷĿ¼
¹©Ó¦ÐÅÏ¢

¹«Ë¾Ãû³Æ£º ÉϺ£Î¤Ã×»úµçÉ豸ÓÐÏÞ¹«Ë¾
µç »°£º 021 31139779 / µË½à
ÊÖ»ú£º 13524123373
µØ Ö·£º ÉϺ£ÊÐÆÖ¶«ÐÂÇø½ðԥ·100ºÅÓíÖݹú¼Ê2ÆÚ2ºÅ907ÊÒ
ÓÊ ±à£º 201206
Ö÷ Ò³£º http://www.weimi.com

¸Ã³§ÉÌÏà¹Ø²úÆ·£º
  • 990-05-XX-01-00 MOD:147202-01±äËÍÆ÷
  •  
  • 990-04-70-01-CN±¾ÌØÀû±äËÍÆ÷
  •  
  • ±¾ÌØÀû±äËÍÆ÷990-04-50-02-00
  •  
  • Bently±äËÍÆ÷990-04-50-01-00
  •  
  • µ¥ÖáÄæ±äÆ÷R911295325 HMS01.1N-W0054-A-07-NNNN
  •  
  • R911295323 HMS01.1N-W0020-A-07-NNNNËÅ·þÇý¶¯Æ÷
  •  
  • R911298372 HCS02.1E-W0070-A-03-NNNN ËÅ·þÇý¶¯Æ÷
  •  
  • ËÅ·þÇý¶¯Æ÷R911298373 HCS02.1E-W0054-A-03-NNNN
  •  
  • R911298371 HCS02.1E-W0012-A-03-NNNN Á¦Ê¿ÀÖËÅ·þÇý¶¯Æ÷
  •  
  • HAS05.1-007-NNR-NN Á¬½ÓÊÊÅäÆ÷
  •  
    ¸ü¶à²úÆ·...
      ¹ØÓÚÎÒÃÇ | ÁªÏµÎÒÃÇ | ¹ã¸æ·þÎñ | ±¾Õ¾¶¯Ì¬ | ÓÑÇéÁ´½Ó | ·¨ÂÉÉùÃ÷ | ·Ç·¨ºÍ²»Á¼ÐÅÏ¢¾Ù±¨  
    ¹¤¿ØÍø¿Í·þÈÈÏߣº0755-86369299
    °æȨËùÓÐ ¹¤¿ØÍø Copyright@ Gkong.com, All Rights Reserved