Ê×Ò³ - ÐÂÎÅ - ÕÐƸ - ÏÂÔØ - ²úÆ· - ³§ÉÌ - ·½°¸ - ÎÄÕª - Çó¹º - Õ¹ÀÀ
Ãâ·Ñ×¢²á µÇ¼ | ¹ã¸æ·þÎñ | ¿Í·þÖÐÐÄ
Öлª¹¤¿ØÍø ¡ú ¹¤¿Ø²úÆ· ¡ú R911170832 CFL01.1-TP³ÌÐòÄ£¿é
²úÆ·Ãû³Æ£º R911170832 CFL01.1-TP³ÌÐòÄ£¿é
ÐÍ ºÅ£º R911170832 CFL01.1-TP
¼Û ¸ñ£º 0.00
Æ· ÅÆ£º
 
Êղش˲úÆ·     ²é¿´ÊÕ²Ø

Á¦Ê¿ÀÖR911170832 CFL01.1-TP³ÌÐòÄ£¿é£»ÉϺ£Î¤Ã×»úµçÉ豸ÓÐÏÞ¹«Ë¾Ö÷ÓªÏúÊÛ²úÆ·£¬²úƷʵÅÄ£¬Ô­×°ÕýÆ·£¬¿Í»§ÂòµÄ°²ÐÄ£¬ÓõķÅÐÄ¡£³£ÓòúÆ·ÏÖ»õ¹©Ó¦£¬»¶Ó­ÐÂÀÏ¿Í»§Ñ¯¼Û²É¹º£¡

 

Á¦Ê¿ÀÖREXROTH×ÜÏßÄ£¿é
R911172194 R-IL PB BK DI8 D04/CN-PAC
Inline PROFIBUS ×ÜÏßñîºÏÆ÷
8 ·ÊäÈ룺24 V DC
4 ·Êä³ö£º24 V DC£¬500 mA
2¡¢3 Ïß½ÓÍ·
Å䱸ÍêÕûµÄ¸½¼þ£¨Á¬½Ó²åÍ·ºÍÌù±êÀ¸£©
Á¬Ðø¶Ë×ÓµãÌù±ê
×ÜÏßñîºÏÆ÷ R-IL PB BK DI8 DO4/CN-PAC ¿ÉÁ¬½Ó PROFIBUS-DP ºÍ Inline °²×°ÏµÍ³¡£Ê¹ÓøÃ×ÜÏßñîºÏ¿É½«ÖÃÓÚÈκÎλÖÃµÄ 62 ̨ Inline ²ÎÓëÉ豸Á¬½ÓÖÁÏÖÓÐ PROFIBUS-DP¡£¸Ã×ÜÏßñîºÏÆ÷ºÍ Inline ²ÎÓëÉ豸×éºÏ³ÉÒ»¸ö°üº¬ 63 ̨±¾µØ×ÜÏß²ÎÓëÉ豸µÄ¹¤×÷Õ¾¡£Òò´Ë£¬×ÜÏßñîºÏÆ÷µÄÊäÈëºÍÊä³ö½«±»ÊÓΪ±¾µØ×ÜÏß²ÎÓëÉ豸¡£
ÖØÁ¿  320g    
´«¸ÐÆ÷Á¬½Ó·½Ê½  2 ÏßÖÆ¡¢3 ÏßÖƼ¼Êõ
Ö´ÐÐÆ÷Á¬½Ó·½Ê½  2 ÏßÖÆ¡¢3 ÏßÖƼ¼Êõ
»·¾³Î¶ȣ¨ÔËÐÐʱ£©  -25 ... +60°C
»·¾³Î¶ȣ¨´¢²Ø/ÔËÊäʱ£©  -45 ... +85°C
ÈÝÐíµÄÏà¶Ôʪ¶È£¨ÔËÐÐʱ£©  95 %£¬²»½á¶
ÈÝÐíµÄÏà¶Ôʪ¶È£¨´¢²Ø/ÔËÊäʱ£©  95 %£¬²»½á¶
Æøѹ£¨ÔËÐУ©  70 kPa ... 106 kPa£¨×î¶à¸ßÓÚ»ùÏß 3000 m£©
¿ÕÆøѹÁ¦£¨´¢²Ø/ÔËÊäʱ£©  70 kPa ... 106 kPa£¨×î¶à¸ßÓÚ»ùÏß 3000 m£©
·À»¤ÀàÐÍ  IP20, IEC 60529
·À»¤µÈ¼¶  III, IEC 61140


Á¦Ê¿ÀÖREXROTHµçÔ´Â˲¨Æ÷
NFD03
ÊÊÓÃÓÚ IndraDrive C, HCS02
ÊÊÓÃÓÚ IndraDrive C, HCS03
R911286918 NFD03.1-480-016
µçÔ´Â˲¨Æ÷È·±£ÁË·ûºÏ EMC ÏÞÖÆ£¬²¢ÇÒÄÜÒÖÖƵçÀµçÈÝÔì³ÉµÄй©µçÁ÷¡£µçÔ´Â˲¨Æ÷¾­×îÓŵ÷ÕûÒÔÊÊÓ¦Çý¶¯¿ØÖƵ¥Ôª£¬²¢ÇÒ¿Éͨ¹ýµçÁ÷¡¢Çý¶¯Æ÷ÊýÁ¿ºÍµç»úµçÀ³¤¶ÈÀ©Õ¹¡£Í¨¹ýÆÁ±Îµç»úµçÀ¿ÉʵÏÖÎÞ¹ÊÕÏÔËÐС£


Á¦Ê¿ÀÖREXROTH¹¦ÄÜÄ£¿éRTÒÔÌ«ÍøºÍPROFIBUS
R911170832 CFL01.1-TP
RTÒÔÌ«Íø£¨PROFINET RT¡¢ÒÔÌ«Íø/IP¡¢ÒÔÌ«Íø TCP/IP£©
PROFIBUS DP
CML¿ØÖÆÆ÷µÄÄ£¿é»¯À©Õ¹
·À»¤µÈ¼¶IP20
ͨ¹ý¸½¼ÓµÄ¼¼ÊõÌØÐÔÀ©Õ¹ÁË¿ØÖƹ¦ÄÜ
À©Õ¹ÁËÓëÆäËû½Ó¿ÚµÄÁ¬½Ó
½«±ê×¼¿ØÖÆÀ©Õ¹µ½SafeLogic°²È«¿ØÖÆÆ÷
¹¦ÄÜÄ£¿é¾ßÓÐʵʱÒÔÌ«ÍøºÍPROFIBUS DPÖ÷É豸»òPROFIBUS DP´ÓÉ豸¹¦ÄÜ¡£¸ù¾ÝÅäÖ㬿ÉÒÔÔÚÄ£¿éÉϽ«²»Í¬µÄÒÔÌ«ÍøЭÒéÓëPROFIBUS DPÒ»ÆðÖ´ÐС£ÒÔÌ«ÍøЭÒé¿ÉÒÔÊÇPROFINET RT¡¢EtherNet/IP»ò±ê×¼TCP/IPµÈ¡£
»·¾³Î¶ȣ¨ÔËÐÐʱ£©  +5 ... +55¡æ
ÈÝÐíµÄÏà¶Ôʪ¶È£¨ÔËÐÐʱ£©  5 % ... 95 %
¹¦ÂÊÏûºÄ  1.65W

Á¦Ê¿ÀÖREXROTH±äƵÆ÷
HCS02 - µ¥Öáת»»Æ÷
1.5 kW ... 11 kW ¹¦ÂÊ·¶Î§
12 A ... 70 A µçÁ÷
200 V ... 500 V Ö±Á÷µçÔ´
2.5x ¹ýÔØÈÝÁ¿
½ô´ÕÐÍÉè¼Æ£¬ÊʺÏÓÚµ¥ÖáÓ¦ÓÃ
IndraDrive C£¨HCS02£©×ª»»Æ÷º­¸ÇÁËÖй¦ÂÊ·¶Î§kW¡£´Ë×°ÖÃÉèÖÃÁËÒ»¸ö¿ØÖƵ¥Ôª²Û£¬Óи÷ÖÖ½Ó¿Ú£¬ÓÃÓÚÁ¬½Ó×Ô¶¯»¯»·¾³£¬ÊÊÓÃÓÚ±àÂëÆ÷ϵͳ¡¢°²È«¼¼Êõ¡¢ºÍÆäËüÊý×Ö¼°Ä£ÄâÐźŵȡ£

Á¦Ê¿ÀÖREXROTHÄ£¿é»¯×ª»»Æ÷
HMS01 µ¥ÖáÄæ±äÆ÷
5.5 kW ... 132 kW ¹¦ÂÊ·¶Î§
12.1 A ... 250 A Á¬ÐøµçÁ÷
12 A ... 350 A ´óµçÁ÷
540 V ... 750 V Ö±Á÷ Ïß·µçѹ
·À»¤µÈ¼¶IP20
HMS01 µ¥ÖáÄæ±äÆ÷ÓÉÖ±Á÷¹©µç£¬²¢Í¨¹ýÖ±Á÷Éú³É±äƵ±ä·ùµÄÊܿؽ»Á÷Êä³öµçѹ£¬ÓÃÓÚÔËÐеç»ú¡£´Ë×°ÖÃÉèÖÃÁËÒ»¸öµ¥Öá¿ØÖƵ¥Ôª²Û£¬Óи÷ÖÖ½Ó¿Ú£¬ÓÃÓÚÁ¬½Ó×Ô¶¯»¯»·¾³£¬ÊÊÓÃÓÚ±àÂëÆ÷ϵͳ¡¢°²È«¼¼Êõ¡¢ºÍÆäËüÊý×Ö¼°Ä£ÄâÐźŵȡ£ÔÚ¶àÖáÓ¦ÓÃÖУ¬Äæ±äÆ÷ͨ¹ý HMV01 »ò HMU05 µçÔ´É豸µÄÖ±Á÷×ÜÏß¹©µç¡£¶ÔÓÚ½ÏСµÄÖá°ü£¬ÒÔ¼°¾ßÓÐÏàÓ¦¶¯Á¦´¢´æµÄ HCS£¬Ò²¿ÉÒÔÓÉ HCS ת»»Æ÷µÄÖ±Á÷×ÜÏß¹©µç¡£
 

Ö÷ÓªÐͺţº

REXROTHÁ¦Ê¿ÀÖRTÒÔÌ«ÍøºÍPROFIBUS CFL01.1-TP
R911170832 CFL01.1-TP
¢È¡¢REXROTHÁ¦Ê¿ÀÖDevice Net CFL01.1-V1
¢É¡¢REXROTHÁ¦Ê¿ÀÖPROFIBUS CFL01.1-P1
R911170005 CFL01.1-P1
¢Ê¡¢Á¦Ê¿ÀÖREXROTH¿ìËÙÊäÈë/Êä³öCFL01.1-E2
R911170365 CFL01.1-E2
¢Ë¡¢Á¦Ê¿ÀÖREXROTH¿É±à³ÌÏÞλ¿ª¹Ø£¨PLS£©CFL01.1-N1
R911170012 CFL01.1-N1
¢Ì¡¢Á¦Ê¿ÀÖREXROTH¾²Ì¬Ëæ»ú´æ´¢Æ÷CFL01.1-Y1
R911170007 CFL01.1-Y1
¢Í¡¢Á¦Ê¿ÀÖREXROTH°²È« CPU CFL01.1-F1
R911170129 CFL01.1-F1
¢æ¡¢Á¦Ê¿ÀÖREXROTHǶÈëʽ¿ØÖÆÆ÷Indra Control XM
1¡¢Á¦Ê¿ÀÖREXROTHǶÈëʽ¿ØÖÆÆ÷Indra Control XM21
R911372463 XM2100.01-01-31-31-001-NN-100N1NN
R911374188 XM2100.01-01-31-31-001-NN-100N2NN
R911345727 XM2100.01-01-31-31-001-NN-100N3NN
R911372897 XM2100.01-01-31-31-001-NN-100NNNN
R911375087 XM2100.01-01-31-31-001-NN-101N1NN
R911374979 XM2100.01-01-31-31-001-NN-101N2NN
R911373799 XM2100.01-01-31-31-001-NN-101N3NN
R911375025 XM2100.01-01-31-31-001-NN-101NNNN
R911377848 XM2100.01-01-31-31-001-NN-102N1NN
R911382416 XM2100.01-01-31-31-001-NN-102N2NN
R911381043 XM2100.01-01-31-31-001-NN-102N3NN
R911374811 XM2100.01-01-31-31-001-NN-102NNNN
R911380757 XM2100.01-01-31-31-001-NN-103N2NN
R911377741 XM2100.01-01-31-31-001-NN-103NNNN
R911375011 XM2100.01-01-31-31-001-NN-104N3NN
R911370766 XM2100.01-01-31-31-001-NN-105N3NN
R911381462 XM2100.01-01-31-31-001-NN-105NNNN
R911345728 XM2100.01-01-31-31-001-NN-108N3NN
R911370489 XM2100.01-01-31-31-301-NN-100N1NN
R911372429 XM2100.01-01-31-31-301-NN-100N2NN
R911345644 XM2100.01-01-31-31-301-NN-100N3NN
R911370639 XM2100.01-01-31-31-301-NN-100NNNN
R911347640 XM2100.01-01-31-31-301-NN-101N1NN
R911376524 XM2100.01-01-31-31-301-NN-101N2NN
R911374784 XM2100.01-01-31-31-301-NN-101N3NN
R911370704 XM2100.01-01-31-31-301-NN-101NNNN
R911377011 XM2100.01-01-31-31-301-NN-102N1NN
R911382450 XM2100.01-01-31-31-301-NN-102N2NN
R911372670 XM2100.01-01-31-31-301-NN-102N3NN
R911373363 XM2100.01-01-31-31-301-NN-102NNNN
R911377225 XM2100.01-01-31-31-301-NN-103N1NN
R911371331 XM2100.01-01-31-31-301-NN-103N2NN
R911376187 XM2100.01-01-31-31-301-NN-103N3NN
R911374809 XM2100.01-01-31-31-301-NN-103NNNN
R911375395 XM2100.01-01-31-31-301-NN-104N3NN
R911380997 XM2100.01-01-31-31-301-NN-105N1NN
R911387880 XM2100.01-01-31-31-301-NN-105N2NN
R911387999 XM2100.01-01-31-31-301-NN-105N3NN
R911373083 XM2100.01-01-31-31-301-NN-105NNNN
R911373699 XM2100.01-01-31-31-301-NN-106N1NN
R911383807 XM2100.01-01-31-31-301-NN-106N3NN
R911373698 XM2100.01-01-31-31-301-NN-106NNNN
R911377846 XM2100.01-01-31-31-301-NN-108N1NN
R911346976 XM2100.01-01-31-31-301-NN-108N3NN
2¡¢Á¦Ê¿ÀÖREXROTHǶÈëʽ¿ØÖÆÆ÷Indra Control XM22
R911346785 XM2200.01-01-31-31-001-NN-100N3NN
R911380465 XM2200.01-01-31-31-001-NN-100NNNN
R911386878 XM2200.01-01-31-31-001-NN-101N1NN
R911376418 XM2200.01-01-31-31-001-NN-101N2NN
R911384672 XM2200.01-01-31-31-001-NN-102N3NN
R911377754 XM2200.01-01-31-31-001-NN-102NNNN
R911373304 XM2200.01-01-31-31-001-NN-105NNNN
R911382917 XM2200.01-01-31-31-001-NN-106N1NN
R911345767 XM2200.01-01-31-31-001-NN-108N3NN
R911370492 XM2200.01-01-31-31-301-NN-100N1NN
R911380330 XM2200.01-01-31-31-301-NN-100N2NN
R911346978 XM2200.01-01-31-31-301-NN-100N3NN
R911370085 XM2200.01-01-31-31-301-NN-100NNNN
R911376420 XM2200.01-01-31-31-301-NN-101N1NN
R911378278 XM2200.01-01-31-31-301-NN-101N2NN
R911369227 XM2200.01-01-31-31-301-NN-101N3NN
R911370638 XM2200.01-01-31-31-301-NN-101NNNN
R911379193 XM2200.01-01-31-31-301-NN-102N1NN
R911372669 XM2200.01-01-31-31-301-NN-102N3NN
R911376005 XM2200.01-01-31-31-301-NN-102NNNN
R911383466 XM2200.01-01-31-31-301-NN-103N1NN
R911380988 XM2200.01-01-31-31-301-NN-103N2NN
R911380872 XM2200.01-01-31-31-301-NN-103NNNN
R911373266 XM2200.01-01-31-31-301-NN-104N3NN
R911380658 XM2200.01-01-31-31-301-NN-105N1NN
R911386986 XM2200.01-01-31-31-301-NN-105N3NN
R911378087 XM2200.01-01-31-31-301-NN-105NNNN
R911373701 XM2200.01-01-31-31-301-NN-106N1NN
R911373700 XM2200.01-01-31-31-301-NN-106NNNN
R911346977 XM2200.01-01-31-31-301-NN-108N3NN
3¡¢Á¦Ê¿ÀÖREXROTHÀ©Õ¹Ä£¿éIndra Control XFE
¢Å¡¢REXROTHÁ¦Ê¿ÀÖSercos III XFE01.1-FB-01
¢Æ¡¢REXROTHÁ¦Ê¿ÀÖRTÒÔÌ«Íø XFE01.1-FB-03/-04
R911173397 XFE01.1-FB-03
R911173937 XFE01.1-FB-04
¢Ç¡¢REXROTHÁ¦Ê¿ÀÖPROFIBUS XFE01.1-FB-10/-11
R911173398 XFE01.1-FB-10
R911173936 XFE01.1-FB-11
¢È¡¢REXROTHÁ¦Ê¿ÀÖCAN XFE01.1-FB-20
¢É¡¢Á¦Ê¿ÀÖREXROTH°²È« CPU XFE01.1-SY-01
R911173399 XFE01.1-SY-01
°Ë¡¢Á¦Ê¿ÀÖREXROTHÊäÈë/Êä³öÄ£¿éI/O
¢å¡¢Á¦Ê¿ÀÖREXROTH IndraControl S20 (IP20)¿ØÖƹñµÄÊäÈë/Êä³öϵͳ
1¡¢Á¦Ê¿ÀÖREXROTHÏÖ³¡×ÜÏßñîºÏÆ÷
¢Å¡¢REXROTHÁ¦Ê¿ÀÖSercos S20-S3-BK+
R911173318 S20-S3-BK+
¢Æ¡¢REXROTHÁ¦Ê¿ÀÖPROFINET RT S20-PN-BK+
R911173359 S20-PN-BK+
¢Ç¡¢REXROTHÁ¦Ê¿ÀÖPROFIBUS S20-PB-BK
R911173247 S20-PB-BK
¢È¡¢REXROTHÁ¦Ê¿ÀÖEthernet S20-ETH-BK
R911173905 S20-ETH-BK
¢É¡¢REXROTHÁ¦Ê¿ÀÖEtherNet/IP S20-EIP-BK
R911173904 S20-EIP-BK
¢Ê¡¢REXROTHÁ¦Ê¿ÀÖEtherCAT S20-EC-BK
R911173906 S20-EC-BK
2¡¢Á¦Ê¿ÀÖREXROTHÄ£ÄâÊäÈëÄ£¿é
¢Å¡¢Á¦Ê¿ÀÖREXROTH8 ÊäÈ룬µçѹºÍµçÁ÷S20-AI-8
R911172536 S20-AI-8
¢Æ¡¢Á¦Ê¿ÀÖREXROTH4 ÊäÈ룬µçÁ÷S20-AI-4-I
R911173249 S20-AI-4-I
¢Ç¡¢Á¦Ê¿ÀÖREXROTH4 ÊäÈ룬µçѹS20-AI-4-U
R911173256 S20-AI-4-U
¢È¡¢Á¦Ê¿ÀÖREXROTHÁ½Â·ÊäÈëºÍÁ½Â·Êä³ö¡¢¹¦Âʺ͵çѹS20-AIAO-2
R911173743 S20-AIAO-2
3¡¢Á¦Ê¿ÀÖREXROTHÄ£ÄâÊä³öÄ£¿é
¢Å¡¢Á¦Ê¿ÀÖREXROTH8 ¸öÊä³ö¶Ë£¬µçѹºÍµçÁ÷S20-AO-8
R911172538 S20-AO-8
¢Æ¡¢Á¦Ê¿ÀÖREXROTH4 Êä³ö£¬µçѹºÍµçÁ÷S20-AO-4
R911173248 S20-AO-4
¢Ç¡¢Á¦Ê¿ÀÖREXROTHÁ½Â·ÊäÈëºÍÁ½Â·Êä³ö¡¢¹¦Âʺ͵çѹS20-AIAO-2
R911173743 S20-AIAO-2
4¡¢Á¦Ê¿ÀÖREXROTHÊý×ÖÊäÈëÄ£¿é
¢Å¡¢Á¦Ê¿ÀÖREXROTH16 ·ÊäÈëS20-DI-16/1
R911172543 S20-DI-16/1
¢Æ¡¢Á¦Ê¿ÀÖREXROTH16 ·ÊäÈëS20-DI-16/1 HS
R911173344 S20-DI-16/1-HS
¢Ç¡¢Á¦Ê¿ÀÖREXROTH16 ·ÊäÈëS20-DI-16/4
R911172532 S20-DI-16/4
¢È¡¢Á¦Ê¿ÀÖREXROTH32 ÊäÈëS20-DI-32/1
R911172533 S20-DI-32/1
¢É¡¢Á¦Ê¿ÀÖREXROTH64 ·ÊäÈëS20-DI-64/1
R911173340 S20-DI-64/1
¢Ê¡¢Á¦Ê¿ÀÖREXROTH8 ·ÊäÈë/Êä³ö£¬1 Ïß¼¼ÊõS20-DIDO-8/1
R911173745 S20-DIDO-8/1
5¡¢Á¦Ê¿ÀÖREXROTHÊý×ÖÊä³öÄ£¿é
¢Å¡¢Á¦Ê¿ÀÖREXROTH8 ·Êä³öS20-DO-8/2-2A
R911172541 S20-DO-8/2-2A
¢Æ¡¢Á¦Ê¿ÀÖREXROTH16 ·Êä³öS20-DO-16/1
R911172542 S20-DO-16/1
¢Ç¡¢Á¦Ê¿ÀÖREXROTH16 ·Êä³öS20-DO-16/3
R911172534 S20-DO-16/3
¢È¡¢Á¦Ê¿ÀÖREXROTH32 ·Êä³öS20-DO-32/1
R911172535 S20-DO-32/1
¢É¡¢Á¦Ê¿ÀÖREXROTH64 ·Êä³öS20-DO-64/1
R911173742 S20-DO-64/1
¢Ê¡¢Á¦Ê¿ÀÖREXROTH8 ·ÊäÈë/Êä³ö£¬1 Ïß¼¼ÊõS20-DIDO-8/1
R911173745 S20-DIDO-8/1
¢Ë¡¢Á¦Ê¿ÀÖREXROTH4 ·¼ÌµçÆ÷Êä³öS20-DOR-4/2-220-AC
R911173749 S20-DOR-4/2-220-AC
6¡¢Á¦Ê¿ÀÖREXROTH¼¼ÊõÄ£¿é
¢Å¡¢Á¦Ê¿ÀÖREXROTHÁ½Â·¼ÆÊýÆ÷ÊäÈë¡¢Á½Â·ÔöÁ¿±àÂëÆ÷ÊäÈëS20-CNT-INC-2/2
R911172539 S20-CNT-INC-2/2
¢Æ¡¢Á¦Ê¿ÀÖREXROTH1 ¸öÓÃÓÚ¾ø¶ÔÖµ±àÂëÆ÷µÄ SSI ½Ó¿Ú£¬1 ¸öÄ£ÄâÊä³ö¶ËS20-SSI-AO-1/1
R911172544 S20-SSI-AO-1/1
¢Ç¡¢Á¦Ê¿ÀÖREXROTH6 ¸öÄ£ÄâÊäÈë¶Ë£¬2 Ä£ÄâÊä³ö¶Ë£¬2 ¸ö SSI ½Ó¿ÚS20-AI6-AO2-SSI2
R911173120 S20-AI6-AO2-SSI2
¢È¡¢Á¦Ê¿ÀÖREXROTH2 PWM Êä³öS20-PWM-2-T
R911173460 S20-PWM-2-T
¢É¡¢Á¦Ê¿ÀÖREXROTH4 PWM Êä³öS20-PWM-4-T
R911173461 S20-PWM-4-T
¢Ê¡¢Á¦Ê¿ÀÖREXROTHÁ½Â·ÔöÁ¿±àÂëÆ÷ÊäÈëS20-INC-2
R911173559 S20-INC-2
7¡¢Á¦Ê¿ÀÖREXROTHζÈÄ£¿é
¢Å¡¢Á¦Ê¿ÀÖREXROTH4 ¸öζȲâÁ¿µç×èÁ¬½ÓÊäÈë¶ËS20-AI-4-RTD
R911173341 S20-AI-4-RTD
¢Æ¡¢Á¦Ê¿ÀÖREXROTH4 ·ÊäÈ룬ÓÃÓÚÁ¬½ÓÈȵçż´«¸ÐÆ÷S20-AI-4-UTH
R911173342 S20-AI-4-UTH
¢Ç¡¢Á¦Ê¿ÀÖREXROTH8 ¸öζȲâÁ¿µç×èÁ¬½ÓÊäÈë¶ËS20-AI-8-RTD
R911172537 S20-AI-8-RTD
¢È¡¢Á¦Ê¿ÀÖREXROTH8 ¸öÈȵçż´«¸ÐÆ÷Á¬½ÓÊäÈë¶ËS20-AI-8-UTH
R911172545 S20-AI-8-UTH
8¡¢Á¦Ê¿ÀÖREXROTHÉýѹģ¿é
¢Å¡¢Á¦Ê¿ÀÖREXROTH Indra Control S20 Éýѹģ¿é£¬ÓÃÓÚÂß¼­µçÔ´ U×ÜÏßS20-PWR
R911173345 S20-PWR
9¡¢Á¦Ê¿ÀÖREXROTHͨÐÅÄ£¿é
¢Å¡¢Á¦Ê¿ÀÖREXROTH RS232 »ò RS485/422 °æ±¾ÖÐÓÐ 1 ¸ö´®ÐÐÊäÈëºÍÊä³öͨµÀS20-RS-UNI
R911173343 S20-RS-UNI
10¡¢Á¦Ê¿ÀÖREXROTH°²È«Ä£¿é
¢Å¡¢Á¦Ê¿ÀÖREXROTH8/4 ¸ö PROFIsafe ÊäÈë¶ËS20-PSDI-8/4
R911173254 S20-PSDI-8/4
¢Æ¡¢Á¦Ê¿ÀÖREXROTH8/4 ¸ö CIP Safety on Sercos ÊäÈë¶ËS20-SSDI8/4
R911173191 S20-SSDI-8/4
¢Ç¡¢Á¦Ê¿ÀÖREXROTH8/3 ¸ö PROFIsafe Êä³ö¶ËS20-PSDO-8/3
R911173255 S20-PSDO-8/3
¢È¡¢Á¦Ê¿ÀÖREXROTH8/3 ¸ö CIP Safety on Sercos Êä³ö¶ËS20-SSDO-8/3
R911173192 S20-SSDO-8/3
¢æ¡¢Á¦Ê¿ÀÖREXROTH Inline (IP20)¿ØÖƹñµÄÊäÈë/Êä³öϵͳ
1¡¢Á¦Ê¿ÀÖREXROTHÏÖ³¡×ÜÏßñîºÏÆ÷
R911170875 R-IL S3 BK DI8 DO4-PAC
R911171944 R-IL PN BK DI8 DO4-PAC
R911171726 R-IL ETH BK DI8 DO4 2TX-PAC
R911172194 R-IL PB BK DI8 DO4/CN-PAC
R911170971 R-IL PB BK DP/V1-PAC
R911296696 R-IL SE BK

¹«Ê¾£º Òò¹¤ÒµÒºÑ¹¡¢×Ô¶¯»¯¸÷½ø¿ÚÆ·ÅƱ¸¼þÐͺŷ±¶à£¬Å·ÃÀ²úÆ·¼Û¸ñʵʱ±ä»¯£¬Òò´ËºÜÄÑʵʱ±ê³ö׼ȷ¼Û¸ñ£¬ÇëÒÔÒµÎñԱʵ¼Ê±¨¼Ûµ¥¼Û¸ñΪ׼£¡ ¸øÄú´øÀ´²»±ã¾´ÇëÁ½⡣

 


¹«Ë¾¼ò½é
²úƷĿ¼
¹©Ó¦ÐÅÏ¢

¹«Ë¾Ãû³Æ£º ÉϺ£Î¤Ã×»úµçÉ豸ÓÐÏÞ¹«Ë¾
µç »°£º 021 31139779 / µË½à
ÊÖ»ú£º 13524123373
µØ Ö·£º ÉϺ£ÊÐÆÖ¶«ÐÂÇø½ðԥ·100ºÅÓíÖݹú¼Ê2ÆÚ2ºÅ907ÊÒ
ÓÊ ±à£º 201206
Ö÷ Ò³£º http://www.weimi.com

¸Ã³§ÉÌÏà¹Ø²úÆ·£º
  • 990-05-XX-01-00 MOD:147202-01±äËÍÆ÷
  •  
  • 990-04-70-01-CN±¾ÌØÀû±äËÍÆ÷
  •  
  • ±¾ÌØÀû±äËÍÆ÷990-04-50-02-00
  •  
  • Bently±äËÍÆ÷990-04-50-01-00
  •  
  • µ¥ÖáÄæ±äÆ÷R911295325 HMS01.1N-W0054-A-07-NNNN
  •  
  • R911295323 HMS01.1N-W0020-A-07-NNNNËÅ·þÇý¶¯Æ÷
  •  
  • R911298372 HCS02.1E-W0070-A-03-NNNN ËÅ·þÇý¶¯Æ÷
  •  
  • ËÅ·þÇý¶¯Æ÷R911298373 HCS02.1E-W0054-A-03-NNNN
  •  
  • R911298371 HCS02.1E-W0012-A-03-NNNN Á¦Ê¿ÀÖËÅ·þÇý¶¯Æ÷
  •  
  • HAS05.1-007-NNR-NN Á¬½ÓÊÊÅäÆ÷
  •  
    ¸ü¶à²úÆ·...
      ¹ØÓÚÎÒÃÇ | ÁªÏµÎÒÃÇ | ¹ã¸æ·þÎñ | ±¾Õ¾¶¯Ì¬ | ÓÑÇéÁ´½Ó | ·¨ÂÉÉùÃ÷ | ·Ç·¨ºÍ²»Á¼ÐÅÏ¢¾Ù±¨  
    ¹¤¿ØÍø¿Í·þÈÈÏߣº0755-86369299
    °æȨËùÓÐ ¹¤¿ØÍø Copyright@ Gkong.com, All Rights Reserved